Troubleshooting
20
3A1182G
Digital Display Messages
No display does not mean that sprayer is not pressur-
ized. Relieve pressure before repair. See
Pressure
Relief Procedure
, page 7
DISPLAY
SPRAYER OPERATION
INDICATION
ACTION
No Display
Sprayer stops. Power is not
applied. Sprayer may be
pressurized.
Loss of power.
Check power source. Relieve pres-
sure before repair or disassembly.
Sprayer is pressurized.
Power is applied. (Pressure
varies with tip size and pres-
sure control setting.)
Normal operation
Spray
Sprayer may continue to
run. Power is applied.
Pressure greater than 4500 psi
(310 bar, 31 MPa) or pressure
transducer faulty
Replace pressure control board or
pressure transducer
Sprayer stops. Power is
applied.
Pressure transducer faulty, bad
connection or broken wire.
Check transducer connection.
Open prime/pressure relief valve.
Substitute new transducer for
transducer in sprayer. If sprayer
runs, replace transducer.
Sprayer stops. Power is
applied.
Line voltage too high.
Check for voltage supply problem
Sprayer does not start or
stops. Power is applied.
Motor fault
Check for locked rotor, shorted wir-
ing or disconnected motor. Repair
or replace failed parts.
Sprayer stops. Power is
applied.
Motor is too hot.
Allow sprayer to cool. If sprayer
runs correctly when cool, check
motor fan function and air flow.
Keep sprayer in cool location. If
sprayer does not run when cool
and continues to blink 6 times,
replace motor.
Power is applied.
Pressure less than 200 psi (14
bar, 1.4 MPa)
Increase pressure if desired.
Prime/pressure relief valve may be
open.
Sprayer stops or does not
start
Low input voltage
Check power source for correct
voltage