Operation
20
3A4180C
4.
Place fluid intake in flushing fluid. Use
water for water base paint and mineral
spirits for oil-based paint. Place drain
tube in waste pail.
5.
Turn prime valve horizontal.
6.
Increase pressure 1/2 turn to start motor.
Hold gun against paint pail. Disengage
trigger lock. Trigger gun and increase
pressure until the pump runs steady and
flushing fluid appears.
7.
Stop triggering gun. Move gun to waste
pail, hold gun against pail, trigger gun to
thoroughly flush system.
8.
While continuing to trigger gun, turn
prime valve down. Then, release gun
trigger. Allow flushing fluid to circulate
until fluid comes out of drain tube clear.
9.
Raise fluid intake above flushing fluid.
10. Turn prime valve horizontal. Trigger gun
into flushing pail to purge fluid from hose.
11. Engage trigger lock.
ti24710a
ti29470a
ti29471a
ti24714a
ti29472a
Summary of Contents for MP 455