2. Hardware Description
AirLive Ether-GSH2404W User’s Manual
8
with the smaller bracket screws. Then attach the remaining bracket to the other
side of the switch.
2. After attached mounting brackets, position the 24 10/100/1000TX plus 4 Mini
GBIC Web Managed switch in the rack by lining up the holes in the brackets with
the appropriate holes on the rack. Secure the switch to the rack with a screwdriver
and the rack-mounting screws.
[NOTE]
For proper ventilation, allow about at least 4 inches (10 cm) of clearance on
the front and 3.4 inches (8 cm) on the back of the Switch. This is especially important
for enclosed rack installation.
2.7 Power
On
Connect the power cord to the power socket on the rear panel of the switch. The other
side of power cord connects to the power outlet. The internal power supply of the
switch works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check
the power indicator on the front panel to see if power is properly supplied.