60
T
he charcoal filter traps odors and must be replaced at least once a year depending on the
frequency of use of the range hood.
W
ARNING: Accessible parts of this appliance may become hot when used with cooking
appliances.
F
or air extraction to be as efficient as possible, use a straight duct or with a minimum of
elbows. Number of technicians recommended for installation: 2 to 3. Use appropriate
wall plugs and screws on the wall where the hood is to be installed. Ask a qualified
installer or technician to select the right dowels and screws. In a cold climate, it is advisable
to install an additional check valve to minimize cold air return, as well as a nonmetallic
thermal barrier to minimize heat transfer by conduction to the outside. The valve must
be installed on the side of the thermal barrier where the air is cold.
T
he thermal barrier must also be installed as close as possible to the point where the duct
enters the heated part of the building.
T
O REDUCE FIRE HAZARDS, USE ONLY METALLIC DUCTS.
I
nstall this hood in accordance with all specified requirements.
T
o reduce the risk of fire and extract air effectively, make sure the exhaust duct faces out.
The extraction mouth must not be open on a space between two walls, ceilings, attics,
reduced spaces or garages.
-T
he code IT cos D for this lamp is DSR-1.5/65-S-64.
Summary of Contents for AHB682IX
Page 1: ...1...
Page 2: ...2 Hotte aspirante Mode d emploi AHB682IX...
Page 19: ...19 Exaustor Manual de instru es AHB682IX...
Page 40: ...40 Cappa Aspirante Manuale di Istruzioni AHB682IX...
Page 56: ...56 Cooker Hood Instruction Manual AHB682IX...
Page 72: ...72...