3. Electric System
3-14
3.1.4
Glow controller (QGS
Ⅱ
)
Part number:44327 04100
(1) Coolant temperature
・
glow instantaneous characteristic ( at the time of key-OFF-ON)
Water temp.°F
(
℃
)
Lamp lights time t1 (sec)
Voltage of No.6 terminal (V)
Glow time t2 (sec)
5 (-15)
5.0
9.5
14.0
32 (0)
3.5
11
6.0
104 (40)
1.8
13
2.4
(2)List of functions
Pin No.
Line
color
Connection
Remark
1
B/W Starter switch C terminal
Detection of starter signal
2
G/W Water temperature sensor
Detection of water temperature
3 B
Earth
4
L/W Controller CN2-14 terminal
Ignition of pre-heating pre-glow (pre-glow) lamp.
5
Y/R Glow relay No.3 terminal
Power supply for glow relay.
When voltage is applied to No.7 terminal, it
pre-heats for a certain time in accordance with the
voltage applied to the water temperature and glow
plug.
When water temperature is lower than 122°F(50
℃
),
it repeats after glow for 15 seconds.
6
L
Glow plug
Detection of glow plug voltage.
7
W/R 10A Fuse
Power supply
8
-
NIL
(3) Chart of function
st
Starter
Switch
t1
Lamp
t2
Glow
15sec
ST
ON
OFF
ON
OFF
ON
OFF
(in case of less than 50
℃
water temperature)
VIEW-A
Discount-Equipment.com
Summary of Contents for PDS185S-6C1
Page 1: ...D i s c o u n t E q u i p m e n t c o m...
Page 19: ...1 Specification 1 15 1 7 Piping Diagram PC08091E D i s c o u n t E q u i p m e n t c o m...
Page 76: ...5 4 PDS185S 6C1 VE PUMP Type PC08047E D i s c o u n t E q u i p m e n t c o m...
Page 77: ...5 5 PDS185S 6C1R IN LINE PUMP Type PC08048E D i s c o u n t E q u i p m e n t c o m...
Page 78: ...5 6 PDS185S 6C1R IN LINE PUMP Type PC08090E D i s c o u n t E q u i p m e n t c o m...