3. Electric System
3-5
・
The dilution of the lubricating oil with fuel caused by the post-injection is kept to a minimum, but
some dilution is possible for low-load operation (low temperature exhaust gas). Make sure that
you do a daily check of oil level.
※
Active regeneration-1 and active regeneration-2 are collectively explained as “active
regeneration” in the instruction manual.
PC14015E
[Manual regeneration]
Although the DPF performs the regeneration control, if the operation conditions with idling at no
load and low speed/low load operation are frequently repeated, the PM may not be combusted. If the
ECU determines that performing the manual regeneration is required at this time, the DPF
regeneration required lamp lights up. If the DPF regeneration required lamp is lit,immediately
conduct the manual regeneration by performing the following operation.