3. Electric System
3-10
2. Timing of each output relay
PC14020E
3. Warning
・
emergency display and emergency stop functions
Item Indicator
Sensor
Actuation
Detecting timing
Time lag
Warning
Discharge temp. H
A-1
Thermister
-
Lamp goes on at
239°F(115
℃
)
Always
120
sec
Water temp. H
A-2
Thermister
-
Lamp goes on at
221°F(105
℃
)
Always
120
sec
Comp. air filter
A-3
Negative
pressure sw. A contact
Differential pressure is
more than
0.9psi(6.23kPa)[0.06bar]
Always
10 sec
Eng. air filter
A-4
Negative
pressure sw. A contact
Differential pressure is
more than
0.9psi(6.23kPa)[0.06bar]
Always
10 sec
Charge A-5
-
-
Charge signal disappears
and lamp goes on
After starting engine 10 sec
Emergency
Discharge temp. H
E-1
Thermister
-
Lamp goes on at
248°F(120
℃
)
Always
1 sec
Water temp. H
E-2
Thermister
-
Lamp goes on at
230°F(110
℃
)
Always
1 sec
Eng. oil press.
E-3
Pressure sw. B contact
Lamp goes on when oil
pressure is lower than
7.1psi(0.049MPa)[0.49bar]
20 seconds after
engine starts
2 sec
Discharge temp.
sensor
E-6 Thermister
-
Disconnected and lamp
goes on
After starting engine
20 sec
Water temp. sensor
E-7
Thermister
-
Disconnected and lamp
goes on
After starting engine
20 sec
・
Warning
:
Compressor continues to run.
・
Emergency
:
Compressor stops.
Discount-Equipment.com
Summary of Contents for PDS185S-6E1
Page 1: ...www discount equipment com D i s c o u n t E q u i p m e n t c o m...
Page 10: ...1 Specification 1 4 Unit mm A131025 D i s c o u n t E q u i p m e n t c o m...
Page 18: ...1 Specification 1 12 1 7 Piping Diagram PC14063E D i s c o u n t E q u i p m e n t c o m...
Page 19: ...1 Specification 1 13 1 8 Fuel Piping PC14001 D i s c o u n t E q u i p m e n t c o m...