(3) Check and confirm the following when faulty charging warning lamp lights on
Measure battery voltage when
stopping
Recharge battery.
Abnormal
: Less than DC12V
Normal: DC12V
Repair alternator because it is in
trouble.
Disconnected check and confirm
waning lamp circuit (L terminal -
emergency controller CN2-11
terminal).
Measure voltage of alternator
BAT terminal during operation
Normal: DC13 to 15V
Abnormal
: Battery voltage is same
as when stopping
Normal: DC13 to 15V
Abnormal
: Higher than DC15.5V Repair alternator because it is in
trouble.
Not cable disconnected
Cable disconnected
Repair emergency controller because
it is in trouble.
Check and confirm battery
voltage at rated speed
Check and confirm that faulty
charging warning lamp circuit
functions correctly