4. Troubleshooting
4-11
4.3
Operation of Emergency Switch
4.3.1
Discharge temperature indication lamp glows and engine stops
Abnormal
More than
104°F(40
℃
)
Faulty
emergency
controller
Less than
104°F(40
℃
)
More than
248°F(120
℃
)
Normal
Check discharge
air temperature
Check resistance
of discharge
temperature
sensor
Relocation
Check wire
connection
between
emergency
controller and
sensor
Replace it
Repair wire connection
Repair it
Not short-circuited
Unsuitable place of
installation
Replenish or replace
Check belt tension
Tension not acceptable or
faulty belt
Check compressor oil filter
Filter clogging
Replace it
Proper
Faulty
Fin tubes much soled
Soiled
Wash or clean
Normal
Normal
Normal
Faulty
Adjust or replace
Check compressor oil level
Faulty wire
connection
between
emergency
controller and
sensor
Less than
248°F(120
℃
)
Faulty sensor
Check oil cooler fin tubes
Check ambient
temperature
Shortage
Abnormality by-pass valve
Check by-pass valve
Abnormality compressor
air-end
Disassemble or repair
No difference
found
Difference found
Check the difference
between temperature at
the inlet of by-pass valve
and at the outlet
Shortage of oil
G
H
I
Short-circuit
Discount-Equipment.com
Summary of Contents for PDS185S-6E1
Page 1: ...www discount equipment com D i s c o u n t E q u i p m e n t c o m...
Page 10: ...1 Specification 1 4 Unit mm A131025 D i s c o u n t E q u i p m e n t c o m...
Page 18: ...1 Specification 1 12 1 7 Piping Diagram PC14063E D i s c o u n t E q u i p m e n t c o m...
Page 19: ...1 Specification 1 13 1 8 Fuel Piping PC14001 D i s c o u n t E q u i p m e n t c o m...