5. Periodic Inspection/Maintenance
5
-
2
5.2 Daily Inspection and Operation Log
Be sure to carry out daily inspection every morning before operation. See Chapter 2 “Operation” of
the manual for the details of inspection.
Pay attention to and carefully observe the following points during daily operation or inspection and
maintenance work. If any trouble or abnormality is found, immediately investigate its cause and
make repairs. If the cause is unknown or not traceable, or if the trouble involves a part or compo-
nent not described in the manual, ask your nearest dealer for information.
(a)Controls and instruments function properly.
(b)Quantity and any leak of water, fuel, and oil or any con-
tamination should be checked.
(c)Appearance, abnormal noise or excessive heat should be
checked.
(d)Loose bolt or nut should be checked.
(e) Any damage, wear or shortage of machine components and
parts should be checked.
(f)Performance of each part or component should be proper.
Keep the operation log to record constant inspection of each component, so that trouble of the unit
can be easily discovered and preventive measures can be taken.
It is very useful to record information such as discharge pressure, oil level, as well as running hour,
maintenance items and replenishment of lubricant on a daily maintenance log.
5.3 Inspection on Separator Receiver Tank
Be sure to carry out the following cleaning and inspection of the separator receiver tank at least once
every year.
(Place to check)
(1) Any damage found on the tank.
(2) Any excessive wear found to fastening bolts on the cover.
(3) Any damage found to pipes and valves etc.
TR0049
Periodic inspection of separator receiver
Summary of Contents for PDSE900S-4B1
Page 1: ......
Page 60: ...8 Specifications 8 2 8 2 Outline drawing A040390 1 A070197...
Page 61: ...9 Wiring Diagram 9 1 A090360E...
Page 62: ...10 Piping Diagram 10 1 10 1 Compression air Compressor oil PDSE900S PDSF830S 4B1 A070141E 2...
Page 63: ...10 Piping Diagram 10 2 PDSG750S 4B1 A070220E 2...
Page 67: ......