10
SET THE OUTLET PRESSURE
When viewed from the front, the left hand outlet valve is adjustable. The right
hand outlet valve will only supply the full reservoir pressure and is not
adjustable.
1. Use the pressure regulator to set
the output pressure of the left
hand outlet valve.
• Turn clockwise to increase the
pressure.
• Turn counterclockwise to
decrease the pressure.
GAUGES
1. The reservoir pressure gauge
shows the current pressure in the
reservoir.
2. The outlet pressure gauge shows
the ‘user set’ outlet pressure. This
can be adjusted as shown above.
REMOVING TOOLS FROM THE AIR
HOSE
1. Push down on the On/Off button
to stop the compressor.
WARNING: ALWAYS SET THE PRESSURE REGULATOR TO ZERO BEFORE YOU
REMOVE OR REPLACE A TOOL.
Summary of Contents for 2244020