14
CHECK THE NON-RETURN VALVE (EVERY 6 MONTHS)
If the reservoir pressure decreases for no apparent reason, it is possible that the
non-return valve is leaking. To check,
1. Make sure that the reservoir is not
under pressure and the
compressor is switched OFF.
2. Examine the non-return valve,
and replace the gasket and valve
if necessary.
SPECIFICATIONS
Max Pressure
8 Bar
Voltage
230 VAC (50Hz)
Air Displacement
14.5 CFM
Receiver Capacity
100 L
Fuse Rating
13 A
Dimensions (L x W x H)
1040 x 440 x 790 mm
Guaranteed Sound Power Level
93 dB(A)
Weight
54 kg