CHECK THE SAFETY VALVE
To make sure that the safety valve works correctly:
1. Unscrew the knurled end and pull
it firmly outwards.
• Air will be released when you
pull the cap out and stop when
released.
2. If the valve does not operate in
this way, do not use the
compressor. The compressor must
be repaired by a qualified service
agent.
3. Screw the knurled end cap back into position.
SET THE OUTPUT PRESSURE
When viewed from the front, the left
hand outlet valve is adjustable. The
right hand outlet valve will only supply
the full reservoir pressure and is not
adjustable.
1. Use the pressure regulator to set
the output pressure of the left
hand outlet valve.
• Turn clockwise to increase the
pressure.
• Turn counterclockwise to decrease the pressure.
GAUGES
1. The reservoir pressure gauge
shows the current pressure in the
reservoir.
2. The outlet pressure gauge shows
the ‘user set’ outlet pressure. This
can be adjusted as shown above.
WARNING: DO NOT REMOVE OR TRY TO ADJUST THE SAFETY VALVE.