GB
the pumping element and see if it needs topping up. For operation at
ambient temperature in the range -5°C to +35°C, use “SAE 5W50”
synthetic oil. The advantage of this oil is that is does not lose its
characteristics either in winter or summer. Do not drain used oil into
the sewer or dispose of it in the environment.
OBSERVE THIS TABLE FOR OIL CHANGES
TYPE OF OIL
HOURS OF DUTY
SYNTHESIS
500
Sinthetic oil
300
Other types of oil mineral multigrade
SAE 15 W40 100
100
WHAT TO DO IF SMALL MALFUNCTIONS OCCUR
Air losses
This can be caused by under tightening of a union
check all unions, wetting them with soapy water.
Compressor not starting
If the compressor has trouble starting, check the following:
Does mains power match that of the data-plate?
Are power cable extensions of adequate diameter or length?
Is the work environment too cold (under 0°C)?
Was the thermal-breaker tripped?
Is there enough oil in the housing to ensure lubrication? (fig. 7)
Is power supplied to the electrical line? (sockets well connected,
thermal- breaker, fuses in good condition).
Compressor not stopping
If the compressor does not stop when maximum pressure is
reached, the tank safety valve comes into operation. To repair the
valve, contact your nearest service centre.
IMPORTANT
Do not on any account unscrew any connection while the tank is
pressurised - always check that the tank is pressure free.
Do not drill holes, weld or purposely deform the
compressed air tank.
Do not perform any maintenance on the compressor unless you
have disconnected the power plug. - Temperature in operating
ambient: 0°C +35°C.
Do not aim jets of water or flammable liquids on the compressor.
Do not place flammable objects near the compressor.
During down-times, turn the pressure switch to “0” position (OFF).
Never aim the air jet at people or animals
Do not transport the compressor while the tank is pressurised.
Take came, as some parts of the compressor, such as the head
and delivery tubes, as they can reach high temperatures. Do not
touch these parts to avoid burns.(fig. 8-9)
Transport the compressor, lifting or pulling it with the appropriate
grips or handles
Keep children and animals well away from the machine operating
area.
If using the compressor for painting:
a) Do not work in closed environments or near to naked flames
b) Make sure there is adequate ventilation at the place of work
c) Protect your nose and mouth with an appropriate mask.
If the electrical cable or plug are damaged, do not use the
compressor and contact an authorised service centre to replace
the faulty component with an original spare part.
If the compressor is located on a shelf above floor height, it must
be secured to prevent it falling while in operation.
Do not put objects or your hands inside the protective grilles to
avoid injury to yourself or damage to the compressor. (Do not use
the
compressor as a blunt object toward things or animals, to
avoid serious damage).
When you have finished using the compressor, always remove the
plug from the power socket.
HINTS FOR EFFICIENT OPERATION
For efficient operation of the machine at full continuing load and at
maximum operating pressure, make sure the temperature of the
work environment indoors does not exceed 25°C.
We advise you to use the compressor at 70% maximum duty per
hour at full load as this ensures efficient operation of the product
long-term.
STORING THE PACKED AND UNPACKED COMPRESSOR
For the whole time that the compressor is not used before unpacking
store in a dry place at a temperature between 5°C and 45°C and
sheltered away from weather. For the whole time that the compressor
is not used after unpacking, while waiting to start it up or due to
production stoppages, place sheets over it to protect from dust, which
may settle on the components. The oil is to be replaced and the
operational efficiency of the compressor is to be checked if it is not
used for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed air with
maximum pressure characteristics that are adequate for the
compressor.Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WITHOUT PRIOR NOTICE WHENEVER NECESSARY.
•
The product has been used for trade, professional or hire
GUARANTEE
Airmec is confident of the quality of its products and offers an
outstanding guarantee. This guarantee statement is in addition to and
in no way prejudices your statutory rights. The guarantee is valid within
the territories of the Member States of the European Union and the
European Free Trade Area. If a product becomes
defective due to faulty materials, workmanship or lack of conformity,
within 24 months from the date of purchase,
guarantees to replace defective parts, repair products subjected to fair
wear and tear or replace such products to ensure minimum
inconvenience to the customer unless:
PROTECTING THE ENVIRONMENT
Separate collection. This product must not be disposed of with
normal household waste. Should you find one day that your
product needs replacement, or if it is of no
further use to you, do not dispose of it with household waste.
purposes;
The product has been subjected to misuse or neglect;
The product has sustained damage through foreign objects,
substances or accidents;
Repairs have been attempted by persons other than authorised repair
agents or service staff. To claim on the guarantee, you
will need to submit proof of purchase to the seller or an authorised
repair agent.
Make this product available for separate collection.
Separate collection of used products an packaging allows
materials to be recycled and used again. Reuse of recycled
materials helps prevent environmental pollution and reduces
the demand for raw materials. Local regulations may
provide for separate collection of electrical products from the
household, at municipal waste sites or by the retailer when you
purchase a new product. provides a facility for the
collection and recycling of products once they have
reached the end of their working life. To take advantage of this service
please return your product to any authorised repair agent who will
collect them on our behalf. You can check the location of your nearest
authorized repair agent by contacting your local office
at the address indicated in the manual.
•
•
Summary of Contents for KA 12180C
Page 3: ...2...