8
Operating Modes
Normal Operating Mode
When the power switch is in the “on” position, the front grill is installed
and no error condition is detected, one of the icon lights will indicate
the “active” mode (low, high or automatic icons as referenced on page 7).
The “active” mode indicator light will be bright when the “active” mode
is first selected, then will dim after 10 seconds and remain on until
another mode button is pressed again.
Grill Removed Mode
If the front grill is removed while the power switch is in the “on”
position, the unit will go into “standby” mode and the “active” mode
indicator light will flash brightly.
Error Mode
If the front grill is installed with the power switch in the “on” position
and one or both of the Reaction Chambers is missing, non-functional
or not seated properly, the unit will enter “standby” mode, causing
all of the indicator lights to flash brightly. This condition can be
automatically cleared by correctly installing two functional
Reaction Chambers.
Change Reaction Chamber Mode
When the Reaction Chambers need to be changed the “active” mode
indicator light will flash dimly. Extreme environments may require
cartridges to be changed every 6 months. Your Airocide will not be
effective in terms of removing pathogens in any matter after the light
has begun flashing and new Reaction Chambers should be installed. See
Maintenance and Cleaning section for details.
No Lights
Indicator lights function only when the unit is plugged in and the power
button is in the “on” position.