background image

                     

    A.C          A.C. INPUT

                      

OUTPUT

        

    NEG

                     

   A.C.    A.C. Input    Battery              

       REMOTE

                      Output  Transfer     Charger

                      POS

         A.C. INPUT

                                                                                              EARTH GROUND

                                                                                 

     EARTH GROUND

WARNING:  CONNECTING THE BATTERY WITH THE WRONG POLARITY TO
THE U.P.S WILL CAUSE DAMAGE THAT IS NOT COVERED UNDER THE WAR-
RANTY.

FIG. 1  INSTALLATION WIRING

   

FUSE

FUSE

+24  FROM  BATTERY

REMOTE  SWITCH

CUSTOMER  INSTALLED  OPTION

Page 7

                  

REMOTE TEMPERATURE SENSE

                                                                                                                               

                              

 24 VDC

Summary of Contents for ADI-24/2400N

Page 1: ...pply External Battery Type OWNERS MANUAL for Models ADI 24 2400N UPS ADI 24 4800N UPS Including Option D Form 121585 121585B OWNER S MANUAL FEBRUARY 2007 Airpax Dimensions Inc 4467 White Bear Parkway...

Page 2: ...AUTION The U P S contains a circuit breaker and capacitor that may produce a spark Do not mount in a confined battery or gas compartment CAUTION Working in the vicinity of lead acid batteriesisdangero...

Page 3: ...ollowing instructions should be thor oughly read and understood before installation 3 02 CAUTION The U P S produces hazardous voltages to avoid risk of harm or fire the unit must be properly installed...

Page 4: ...put is also presented behind the wiring compartment panel for direct hardwire wire leads The black wire is hot 2 black hot wires with D option the white wire is neutral and the green wire is ground Th...

Page 5: ...tached to the inverter Use the following table to determinecorrectsetting BATTERY CAPACITY SELECTOR SETTING AMP HOUR CAPACITY A Over 600 B 600 400 C 400 200 D Less than 200 4 05 To operate the U P S t...

Page 6: ...ernalcircuitbreakersorfuses b The green Timer Complete light indicates theunit sbatterychargerwasunabletocompletely charge the batteries during the 12 hour charge cycle One or more of the following co...

Page 7: ...NPUT EARTH GROUND EARTH GROUND WARNING CONNECTING THE BATTERY WITH THE WRONG POLARITY TO THE U P S WILL CAUSE DAMAGE THAT IS NOT COVERED UNDER THE WAR RANTY FIG 1 INSTALLATION WIRING FUSE FUSE 24 FROM...