Main battery
The 12 V main battery is mounted on the engine side of the firewall.
Main bus
Refer to paragraphs 7.19.1 and 7.19.2.
When power to the main bus is lost / fails / is removed (i.e. Master switch
turned off) the following equipment becomes non-operational:
1.
Main fuel pump.
2.
Flaps.
3.
Autopilot (i.e. the autopilot servos).
4.
Propeller control.
5.
Radio and transponder.
6.
Strobe, navigation and taxi lights.
7.
Starter.
8
EFIS (unless powered by the EFIS battery back-up circuit).
9.
The charge system relay is de-energized and disconnects the charge
system from the battery and main bus.
10. TCU (Turbocharger Control Unit) / waste gate servo.
With regard to the above:
1.
The auxiliary fuel pump can be operated via the charge system
output, provided that the alternator / charge system remains operational.
2.
The EFIS and related equipment (iBOX, RDAC) can be operated via
the EFIS back-up battery circuit, provided that the circuit is switched on.
3.
The propeller controller and propeller pitch actuator motor are not
powered and the propeller essentially becomes a fixed pitch propeller at
the last pitch setting it was commanded to (by the propeller controller).
If
pitch is in the flight range, then continued safe flight is possible