You have taken the first step in creating a healthy environment. It should 
be noted that this purifier is not intended to be the main protection against 
pollutants. The source of your pollution should always be eliminated or 
reduced. The purifier will sustain clean air in your space. This air purifier is not 
intended for industrial use.

GETTING STARTED

When you receive your unit, turn on the unit to the MAX level and allow it to 
run for at least 30 minutes to burn off any residuals from transport and allow 
filters to settle in.

REGULATING FAN SPEED

The purifier can be set to run at variable speed settings allowing you to 
control your air flow.

GUIDE TO GETTING CLEAN AIR  

AT HOME

30 

min

Maximum setting

Low setting

Purifier turned off

Summary of Contents for V600

Page 1: ...1 V600 AIR PURIFIER ...

Page 2: ...CONTENTS IMPORTANT SAFEGUARDS 4 THE AIRPURA SYSTEM 5 GETTING CLEAN AIR AT HOME 6 HOW TO CHANGE YOUR FILTER 8 TECHNICAL SPECS 13 WARRANTY 14 ...

Page 3: ...your purchase of the Airpura air purifier Please read this user manual carefully before operating to familiarize yourself with the unit and the proper usage of it Keep this user manual in a safe place for future reference ...

Page 4: ... cloth to remove any dust from packaging Please ensure air purifier is turned OFF when plugging into a power source Failure to do so may result in motor potentially stalling and or burning Plug the unit into a regular grounded 110 volt outlet Cleaning and user maintenance should not be made by children without supervision Appliances that are obviously damaged must not be operated IMPORTANT SAFEGUA...

Page 5: ...taminants such as dust pollen pet dander and mold spores while protecting lifespan of main filters CARBON FILTER Our purifiers contain 18 26 lbs of activated carbon that will adsorb airborne chemicals gases and odors ONLY CLEAN AIR HEPA efficiency filter in a pressure sealed filter chamber traps 99 97 of airborne particles as small as 0 3 microns THE AIRPURA SYSTEM EXPERIENCE THE EVOLUTION OF CLEA...

Page 6: ...r in your space This air purifier is not intended for industrial use GETTING STARTED When you receive your unit turn on the unit to the MAX level and allow it to run for at least 30 minutes to burn off any residuals from transport and allow filters to settle in REGULATING FAN SPEED The purifier can be set to run at variable speed settings allowing you to control your air flow GUIDE TO GETTING CLEA...

Page 7: ... effect on the performance of the carbon When using purifier with a humidifier please keep humidifier at least 6 feet away At the beginning of product use it is possible the carbon filter may emit an odor This smell will dissipate after 2 weeks It is not recommended to operate purifier in area where food is being cooked particularly near fish meats and fried foods Oil on carbon filter can shorten ...

Page 8: ...mal conditions 3 months for high pollution levels 2 Particle filter HEPA 600RVHU Filter 99 97 efficient 0 3 Microns 5 years under normal conditions 3 years for high pollution levels 3 Chemical gas odor filter 18 lbs Enhanced Carbon Blend 17 potassium iodide 83 coconut shell 2 years under normal conditions 1 year for high pollution levels PREFILTER HANDY TIP The prefilter can be vacuumed from the e...

Page 9: ...2 Remove cover 2 Replace with the new HEPA filter Ensure the open side of the HEPA filter is placed headfirst 3 Remove gasket and set aside OPENING THE FILTER CHAMBER REPLACING THE HEPA Before attempting to replace your filters follow steps to open the filter chamber SAFETY NOTE Power must always be disconnected when replacing your filters ...

Page 10: ...on filter Be careful when lifting out A used carbon filter is heavy 5 Insert the carbon filter into the top of the funnel and allow to slide in 3 Take your filter slider and roll into a spiral supplied with purchase of replacement carbon and HEPA filters 6 Pull the filter slider out allowing the carbon to slide to the bottom of purifier 7 Replace the HEPA filter that had been set aside REPLACING T...

Page 11: ... the bottom of purifier 6 Insert the tube into the filter chamber inside the prefilter opening the top of the spiral to make a slight funnel 9 Replace the HEPA filter that had been set aside 7 Insert the carbon filter into the top of the funnel and allow to slide in REPLACING THE PREFILTER 1 Remove the HEPA filter located in the center of the unit and set aside 2 Remove the carbon filter and set a...

Page 12: ...d your air filtration needs change in the future Prefilter HEPA Particle filtration Carbon Chemical gas odors Upgrade HEPA 14 Filter 99 99 of airborne particles 0 3 microns ULPA Filter 99 9999 of airborne particles 0 1 microns 18 lbs impregnated carbon filter 17 potassium permanganate carbon 83 coconut shell carbon The potassium permanganate is a powerful oxidizer that accelerates the binding of V...

Page 13: ... H X 13 25 OD X 9 ID Carbon Bed 2 deep Air Flow 560 cfm More cfm than any other home unit available Prefilter 570 in2 x 1 in Housing Powder coat steel Size 23 in x 15 in Weight 47 lbs total Watts 120 on high 40 on low Sound Level 28 1 db on low at 6 feet 62 3 db on high 560 cfm Room level 25 1 db Voltage options 110V 120V or 220V 240V 50 60 Hz ETL Certified no 113 ANSI UL 507 3067330 60950 CA 1727...

Page 14: ...t parts deemed necessary by Airpura Industries will be charged to the purchaser The same warranty applies to the Airpura I600 within two 2 years of purchase for parts and labor and within 5 years for labor only Obvious defects must be communicated to the Authorized Dealer within 10 days from the purchase date This warranty shall not apply to damage caused through misuse wear and tear neglect unaut...

Page 15: ......

Page 16: ...www airpura com Toll free 1 866 505 7872 Local 450 978 9020 ...