REQUIRED TOOL & SUPPLIES NOT INCLUDED
In addition to the included items listed above, the following tools and supplies are required to install the
Make-Up Air Unit:
• Safety Glasses, Gloves
•
• Cutter / Jig Saw
• Heat Gun to install/remove the 1/8” vinyl tubing to the barbs of the sensor and inlet plates.
• Cordless screwdriver with Phillips head and miscellaneous drill bits, driver bits and sockets
• Hardware to mount Outside Air Opening, Duct, Framing etc.
• High quality caulk /sealant / duct tape
• Lumber to create a cradle or MUA mounting frame and/or Metal to create mounts for the MUA units
modules (corner screw mounts).
• Fishing tape or similar tool (to pull tubing and cables through the wall)
• 1/8” I.D. vinyl tubing, from living space to the controller, from outside to the controller (Note: install guide)
1/8” I.D. vinyl tubing, from V-Bank Filter Box to the controller (2pcs) (if the option was purchased)
• 1/8 barbed air ports (2x, +bug screen) for mounting the pressure tubing in the living space and to the
outside.
• Return Air (recirc.) Inlet with grille and duct and/or adapter and 18" flex duct. A connection to the house
return air ducting may be convenient.
• Outside (make-up) Air inlet with bug guard and duct and/or adapter and 18" flex duct
• Supply (make-up air) Fan outlet with grill and duct and/or adapter and 18" flex duct
• Two standard electrical sockets (single 15A)
• Hood and Fire Interlock dry contacts and wiring (not incl)
• Conduit to run low voltage wiring.
• Coil Box requires a hot water or glycol plumbing system, hot water source, pump and a valve to control
(0-10VDC or 24VDC PWM) the volume including wiring to control the valve.
• An Ethernet cable to connect the controller to a wireless router (not incl.)
• A wireless router (not incl.)
• A wireless capable Tablet or mobile phone or a PC on a local network (not incl.)
ELECTRICAL REQUIREMENTS
model requires a dual socket 120 volt, Single Phase, 60 Hz, 15A
uninterrupted power supply. These specifications must be taken into account when allocating power from
existing circuits. We strongly recommend providing a dedicated circuit.
This Circuit MUST be Ground Tested.
This can be done easily using a
available at most
hardware stores. This fan and controller each has a factory-installed, 20 ft. power cord. Consider this
length when choosing a location for this fan. Depending on the location of existing outlets in the
installation space, the installation of an additional outlet may be required.
NOTE: if a GFCI is used it MUST be a Motor Rated GFCI
All wiring and connections must be made according to this manual and acceptable wiring standards. All
local codes must be followed. Consult an electrician if necessary.
© AirScape MUA-IOM, July 2022, All Rights Reserved.
6