(Configuration 4- MUA UNIT ONLY)
MAKE-UP AIR UNIT WITH:
- Fan Module (20 ft Power Cord)
- V-Bank Filter Module (MERV13)
- MUA Controller (10 ft Power Cord)
- Cat5 Fan Cable (10 ft)
OPTIONAL MUA ADDITIONS THAT CAN BE ADDED TO ALL CONFIGURATIONS:
HOT WATER COIL BOX:
Use Hot Water or Glycol to Heat the Make-Up Air coming in.
The Coil Assembly must be installed between the fan and the filter
modules. (½” plumbing connections, bottom feed)
The Coil has been designed for closed loop systems, separated
from domestic water systems (the coil is not “drinkable” water rated)
NOTE: Setting up a water heating coil system may involve plumbing and controls that are beyond the
average skillset. If in doubt of any safety on control concerns, please contact AirScape technical support at
or by email at
or consult a professional.
IN PARTICULAR IT IS
CRITICAL TO AVOID CONTAMINATING DOMESTIC WATER SYSTEMS.
Filter Differential Pressure Sensor:
Alerts you to dirty filters.
The Additional 500 Pascal pressure sensor, harness and mounting hardware is
installed into the controller box. The additional software abilities are unlocked in the
software config.
It furthermore requires 1/8” I.D. Vinyl tubing to connect the two sensor ports to the
filter module’s two static ports (2 x tubing, which is not included).
SYSTEM INSTALL GUIDE
is going to be placed in the attic or mechanical room and can be difficult to
access once installed. It is wise to “plan” and document your Make-Up Air Unit Installation. Picking a
location for the make-up air unit is very important and will influence the cost of the installation. Consider
the length of duct, accessibility, and routing to ensure an efficient installation.
Unit installation:
The unit aught to be placed within reach of the 20 foot long power cord to an existing receptacle outlet.
This may eliminate the need for an electrician if possible and will reduce the cost of the installation.
Mount the unit on top of the ceiling frame (attic), or on top of a frame. You can hang the unit with a
support frame and threaded rod. Mechanical Installation Options are an Attic Installation, installation in
© AirScape MUA-IOM, July 2022, All Rights Reserved.