Machine Error Codes
Error Code
Solution
Check heater clamp is down all the
way.
•
Check that the heater clamp is down
•
This error will clear when the clamp is in the
down position.
The film roll is not moving. This can
be due to no film on the roller or in
the feed rollers.
•
Check the roller has material on it.
•
Check the film is fed correctly onto the nozzle
•
Check the film is being pulled all the way
through the heating element block and the feed
rollers.
The heating element is not heating.
Please check wiring.
•
Check all wires going to the heating elements.
•
If no loose wire is seen, call Better Packages
Service for assistance
•
Once the problem has been fixed, turn the
machine off and then on
Over temperature condition has
been detected. Check temperature
sensor and heater block.
•
Check for signs of over temperature, burnt
belts, etc.
•
If signs of burnt belts are present, Call POLYAIR
Customer Service for assistance.*
•
If no sign of burnt belt is present, replace Upper
Heater Block.
Temperature reading out of range.
Check temperature sensor.
•
Replace Upper Heater Block.
•
Call POLYAIR Customer Service for assistance.*
Motor rotation has been stopped.
Check for film jam.
•
Check feed roller for a film jam.
•
If no film jam is seen, Call POLYAIR Customer
Service for assistance.*
Broken Belt or Belt Switch Activated
•
Replace both upper and lower belts.
POLYAIR Customer Service 1-800-457-3961