AirSpeed 1050 Installation Guide
DUG01545
Airspan Commercial and Internal Use
15
2 Verifying Prerequisites
Prior to installing the AirSpeed 1050, verify the required safety, power, tools, parts and components.
This chapter includes the hardware, software, and client requirements for installation. Verify the
availability of:
AirSpeed 1050 unit
Mounting Kit
Desired location with available power source
2.1 Verify the Tools
Table 4. Hardware Requirements - Mounting
Tool
Use
Large flat bladed screwdriver
securing the pole straps
13 mm wrench
for securing the M8 bolts
13 mm torque wrench
for final tightening of the M8 bolts
(Tighten to a torque of no more than 14 Nm (10
ft-lb) max.)
Knife
For cable preparation
Small side cutters
For power cable preparation
Wire strippers
For power cable preparation
2.2 Verify the Parts and Kits
Note:
Verify order and requirements to ensure the correct unit type is being installed.
Note:
Currently available - AS105-U40-B08D (DC variant).
Table 5: AirSpeed 1050 Components
Installation Kit / Part
Product Code
AS P/N
Description
AirSpeed 1050 B40
Fiber + copper BH,
DC power
AS105-U40-B08D
998-73-401SF
AirSpeed 1050, 2.3 - 2.4 GHz (B40), Fiber,
Copper Backhaul, DC
Nut, M6, Full, SS, A2, DIN934 (x2)
Spring Lock Washer M6 SQ End SS
A2 DIN127B (x2)
HEX Head Screw M6x30mm, SS A2
DIN933 (x1)
AirSpeed 1050 B40
Fiber + copper BH,
AC power
AS105-U40-B08A
N/A
AirSpeed 1050, 2.3 - 2.4 GHz (B40), Fiber,
Copper Backhaul, AC
Mounting Kit (Pole)
Mounting KIT
Long Band
903-03-350
Pole Mounting Clamp Bracket (x1)
Sems Hex-Head Bolt M8x20 ISO4017
with 2 Washers-all A2 (x2)
Maxi Clamp, band 14mm (9/16in) wide
+ quick adjust lock, 63-406mm (1/2-