AirSpeed 1050 Installation Guide
DUG01545
Airspan Commercial and Internal Use
37
12. Lift the lever of housing base slightly so that the rubber gland, tightening cone and gland nut
can be inserted and tightened correctly.
Figure 51: Lift Lever
13. Push to insert the rubber gland.
Figure 52: Insert Gland
14. Push to insert the tightening cone.
Figure 53: Insert Cone
15. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 –
1.84 ft-lb) max.
Figure 54: Tighten Gland Nut