background image

 AirVelocity 1500 Installation Guide  

DUG01560

 

Airspan Commercial and Internal Use 

23 

 

4.2 Wall Mount Assembly 

The following defines the wall mounting procedure. 

1. 

Determine the required location where the AirVelocity unit is to be installed on the wall. 

 

Figure 14: Assemble Rail Brackets to the Unit 

 

 

2. 

Utilize the marking template supplied with the AirVelocity unit and position it against the 
wall where the unit is to be mounted. Be sure to position the template 

straight and level

 

mounting

 

to ensure the unit sits level. 

 

3. 

Mark the holes positions carefully through the template (supplied) onto the wall. 

4. 

Drill the four (4) holes. After drilling insert wall plugs (x4) (not included). 

Note:

 Wall plugs (x4) and necessary hardware are 

not

 supplied by Airspan and are the 

responsibility of the installer. Use appropriate wall plugs according to field conditions. 

 

5. 

Drive the screw(s) into the wall just far enough for the screw heads to stick out from the 
wall, slightly more than the shoulder thickness of the head of the screw in order to hold 
the Rail brackets snugly. 

 

Figure 15: Insert Anchors & Screws in Wall 

 

 

6. 

Place the AirVelocity’s Rail brackets onto the screws heads protruding from the wall. 

Summary of Contents for AirVelocity 1500

Page 1: ...AirVelocity 1500 Installation Guide Part Number DUG01560 System Release 16 5 Revision A Published March 2019 ...

Page 2: ...of any information facts and or opinions contained therein No responsibility is assumed by Airspan Networks Ltd for the use of the documents nor for the rights of third parties which may be effected in any way by the use thereof The provision of these documents and the documents themselves does not constitute professional advice of any kind Any representation s in these documents concerning perfor...

Page 3: ...Safety 2 Warning of Hazardous Voltages 3 Adherence to European Directive 2014 53 EU 4 Warning Symbols 4 Service Information 4 UL Information 4 DECLARATION OF CONFORMITY 5 Maximum Output TX Total Power 7 Product Variants 7 Power Consumption 7 LTE Antenna System 8 Integral Sectorial Antenna 8 About This Document 9 Purpose 9 Intended Audience 9 Document Conventions 9 Related Reading 9 Customer Care H...

Page 4: ... 2 4 Verify Components 14 3 2 5 Physical Dimensions 15 3 2 6 Environmental 16 4 AirVelocity 1500 Installation 17 4 1 Ceiling Mount 17 4 1 1 Suspended Ceiling Assembly 17 4 1 2 Conventional Ceiling Assembly 21 4 2 Wall Mount Assembly 23 4 3 LED Display 25 5 Connect and Manage Cables 26 5 1 DC Cable Connection 26 5 2 Mounting the AC to POE DC Power Supply 26 5 3 Ethernet Cable Installation 26 5 3 1 ...

Page 5: ...eiling 21 Figure 12 Mounting AirVelocity 1500 on Conventional Ceiling 22 Figure 13 Insert Secure Locking Pin 22 Figure 14 Assemble Rail Brackets to the Unit 23 Figure 15 Insert Anchors Screws in Wall 23 Figure 16 Insert Anchors Screws in Wall 24 Figure 17 Push Down to Engage Screw Heads 24 Figure 18 DC Power Plug 26 Figure 19 DC In Panel 26 Figure 20 GPS Antenna 27 Tables Table 1 AirVelocity 1500 ...

Page 6: ...bstract This document details procedures for installing the Airspan s AirVelocity 1500 Indoor Pico Enterprise eNodeB variant Revision History Revision Details Date Summary of Changes Rev 0 1 January 2019 Initial document draft comments Rev 0 2 0 4 March 2019 comments new mounting variations Rev A March 2019 comments Update EU Directive Publish Rev A1 March 2019 Added bracket assembly on the unit ...

Page 7: ...the user s authority to operate the equipment General Only qualified personnel should be allowed to install replace and service the equipment The device cannot be sold retail to the general public or by mail order It must be sold to operators Installation must be controlled Installation must be performed by licensed professionals Installation requires special training The AirVelocity 1500 should b...

Page 8: ...quirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance Warning of Hazardous Voltages On AC installations hazardous voltages exist Use caution when verifying or working with AC power Remove metal jewellery that could come into contact with AC power On DC sections short circuiting the low voltag...

Page 9: ... standard safety practices before continuing Caution hot surface Caution Electro Magnetic Radiation DC Service Information Refer all repairs to qualified service personnel Do not modify any part of this device as this will void the warranty Disconnect the power to this product and return it for service if the following conditions apply a The terminal does not function after following the operating...

Page 10: ... exigible de la Directiva 2014 53 UE Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ ΠΡΟΔΙΑΓΡΑΦΗ η Airspan ΔΗΛΩΝΕΤΑΙ ότι η μονάδα συμμορφώνεται με τις ουσιώδεις απαιτήσεις και τις λοιπές σχετικές διατάξεις της οδηγίας 2014 53 ΕE Français Airspan déclare par la présente que l appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 2014 53 UE Italiano Con la presente Airspan dic...

Page 11: ...ice 2014 53 EÚ Suomalainen Airspan vakuuttaa täten että laitteen tyyppi on direktiivin 2014 53 EU olennaisten vaatimusten ja muiden asiaankuuluvien säännösten mukainen Swedish Därmed intygar Airspan att denna enhet överensstämmer med de väsentliga egenskapskraven och andra relevanta bestämmelser som anges i direktiv 2014 53 EU Íslenska Airspan lýsir hér með yfir að þessi eining uppfylli grunnkröfu...

Page 12: ...ocity supports the following frequency bands with the specific performance values Table 2 Supported Frequency Bands Band Product Code Downlink Freq MHz Uplink Freq MHz Duplex Tx Power per Channel dBm mW 48 42H 43L VNG15 U48 B08P3D 3550 3700 3550 3700 TDD 20 99dBm Power Consumption AirVelocity 1500 has a maximum nominal power consumption of 30W AirVelocity 1500 power consumption is described in the...

Page 13: ... which is an inseparable part of the unit Use of an external antenna is not part of the product design LTE Antennas AirVelocity 1500 has a sectorial antenna that behaves as an Omni antenna for ceiling mount and Directional antenna for wall mounting Note The integral LTE antenna included is dependent on the product s LTE band Table 4 Integral Sector Antenna Parameters LTE Frequency GHz Boresight ga...

Page 14: ...phic Conventions Convention Element Blue underlined text Cross reference links Bold text Keyboard buttons and GUI elements Command Command names or phrases Computer output Text displayed by the computer Hyperlinks Website and e mail addresses Danger Signifies a hazardous situation if not avoided will cause death or serious injury Describes how to avoid it Warning Signifies a hazardous situation if...

Page 15: ...ends an issue number for your reference The system uses this issue number to categorize and store e mails under the appropriate issue To help Customer Care Help Desk identify your issue include the issue number and your Customer Care Helpdesk account details in all further communications Main Operations Airspan Communications Ltd Capital Point 33 Bath Road Slough Berkshire SL1 3UF United Kingdom T...

Page 16: ... ceiling mounting AirVelocity 1500 is a high performance indoor pico eNB supporting a single sector non contiguous dual carrier solution that can support up to a total of 40MHz bandwidth AirVelocity 1500 employs Software Defined Radio SDR technology together with two transmit paths two receive paths antennas and clock synchronization all in a highly integrated physically small and light targeted t...

Page 17: ...span Commercial and Internal Use 12 2 Getting Started 2 1 AirVelocity 1500 Installation Checklist Plan the installation of the AirVelocity 1500 by using the Installation Checklist which you can find as a removable job aid in Appendix B for this guide ...

Page 18: ...king nuts when mounting 3 2 2 Verify the Parts and Kits Note Verify order and requirements to ensure the correct unit type is being installed Table 7 Parts Kits Installation Kit Part Part No Airspan No Consisting of Note AirVelocity 1500 3 55 3 70 GHz VNG15 U48 B08P3D 998 13 481 998 13 481MS AirVelocity 1500 BTS 3 55GHz B48 Ethernet copper backhaul POE DC input including P N 402 00 813 brackets Qt...

Page 19: ...e not included with the AirVelocity 1500 and can be ordered separately Table 8 AirVelocity 1500 Power Supply Options Installation Kit Part Part No Airspan No Note POE PSU 60W IN 100 240VAC OUT 56VDC 1 2A US AC Cable VNG PSU US ID POE 1 903 03 110 One per unit AC ADAPTER 60W IN 100 240VAC OUT 12VDC 5A US AC Cable VNG PSU US ID AC 1 903 03 111 One per unit Note Unit variant determines the PSU type r...

Page 20: ... Part Dimensions H x W x D AirVelocity 1500 250 x 250 x 60 mm 9 84 x 9 84 x 2 36 in Mounting plate for unit ceiling 160 x 163 1 mm x13 50 Height Rail plate ceiling 52 9 x 52 9 mm x 18 mm plate pins Rail Bracket ceiling wall comes assembled on the AV 1500 unit 64 x 55 50 mm x 17 50 Height 3 2 5 2 Weight The weight of all AirVelocity components are listed below Table 11 AirVelocity 1500 Components W...

Page 21: ...t temperature controlled locations xETSI EN 300 019 1 2 Transportation Table 12 AirVelocity 1500 Environment Compliance Type Details Standard Compliance Operating temperature 5 C to 40 C ETSI 300 019 1 3 Class 3 1 Operating humidity 5 85 non condensing ETSI 300 019 1 3 Class 3 1 Storage temperature 20 C to 70 C N A Storage humidity 5 95 non condensing N A Ingress protection IP40 N A Operational al...

Page 22: ...nd a conventional ceiling Note Prior to assembly in any mounting scenario determine where the unit it to be installed 4 1 1 Suspended Ceiling Assembly 1 Determine the optimal position where the AirVelocity unit is to be installed at an intersection between the suspended ceiling rail supports 2 Remove the AirVelocity unit from the packaging and assemble the two 2 rail brackets supplied using the fo...

Page 23: ...ls onto the suspended ceiling s rail supports Figure 5 Ceiling Mounting Plate Rails onto Ceiling Rails 9 Slide the triangular Rail plates 4 so that they clinch the ceiling rails at the rail s intersection Figure 6 Slide and Clinch the Rail Plates onto the Ceiling Rails 10 Tighten the four 4 wing nuts 11 Lift the AirVelocity unit into position and engage the Rail bracket projections so they enter i...

Page 24: ...tions are in the slots swing the unit into the other side of the Ceiling mounting plate insert and secure the Locking pin supplied through the hole on Rail bracket and the Ceiling mounting plate Figure 8 Swing Unit into Place and Insert the Locking Pin 13 Once the Locking pin has been secured insert and click closed the Safety cable supplied Figure 9 Insert and Click Close the Safety Cable ...

Page 25: ...plastic cover to expose the connectors 15 Connect the necessary cables to the relevant ports Connect to power Copper Ethernet port ETH if applicable Fiber Ethernet port SFP if applicable GPS cable to the GTPS port when required Debug port if needed 16 Once all connections are completed replace cover ...

Page 26: ...mounting plate straight to ensure the unit sits as required 4 Mark the screw positions carefully through the diagonal slots on the Ceiling mounting plate onto the ceiling 5 After drilling holes and inserting approved ceiling anchors plugs fasten the Ceiling mounting plate to the ceiling with approved screws and washers not included Figure 11 Attach Mounting Bracket to Standard Ceiling 6 Mounting p...

Page 27: ...t and secure insert and secure the Locking pin supplied through the hole on Rail bracket and the Ceiling mounting plate Figure 13 Insert Secure Locking Pin 9 Remove the plastic cover to expose the connectors 10 Connect the necessary cables to the relevant ports Connect to power Copper Ethernet port ETH if applicable Fiber Ethernet port SFP if applicable GPS cable to the GTPS port when required Deb...

Page 28: ...to ensure the unit sits level 3 Mark the holes positions carefully through the template supplied onto the wall 4 Drill the four 4 holes After drilling insert wall plugs x4 not included Note Wall plugs x4 and necessary hardware are not supplied by Airspan and are the responsibility of the installer Use appropriate wall plugs according to field conditions 5 Drive the screw s into the wall just far e...

Page 29: ...Installation Guide DUG01560 Airspan Commercial and Internal Use 24 Figure 16 Insert Anchors Screws in Wall 7 Push down slightly to engage the heads of the screws onto the slots Figure 17 Push Down to Engage Screw Heads ...

Page 30: ...owering up refer to the following table for indication of current status Table 13 LED Display Name Color Status Description eNB Status LED OK LED Powering Up White On Continuously Till the eNodeB SW starts loading Software initiating Green Blinking 3Hz During initiating process till All Running Normal Operation Blue On Continuously Normal operation no alarm Major Alarm Yellow Orange On Continuousl...

Page 31: ...e AirVelocity 1500 unit Mount the power supply with screws through the two 2 holes on the unit s frame The power supply should be mounted close to an available electrical outlet 5 3 Ethernet Cable Installation Before connecting to the appropriate port you can manage and store any excess cable by winding it and tying it off This takes up any excess slack and presents a more thorough and orderly ins...

Page 32: ...fferent installation options Option 1 Installation on the inside of a window 1 Remove the paper from one side of the double sided sticker and attach the sticker on the front side of the antenna 2 Thoroughly clean the area of the window where you intend to attach the GPS antenna 3 Remove the paper from the other side of the sticker and fix the antenna on the window from the inside Verify there are ...

Page 33: ...o firmly tighten the SMA connector 6 Seal the hole with a sealing material RTV or similar 7 Route the cable to the base station and connect it to the GPS port on the base station Make sure to firmly tighten the SMA connector Option 3 installation on a mounting bracket 1 Take the supplied bracket and attached it to the wall using one or two screws and appropriate wall plugs screws are not supplied ...

Page 34: ... ladders elevated work platform o Available AC outlet o Configuration programming details known o Point of connection for Ethernet o All equipment items available at the installation site o Air Velocity 1500 unit o Mounting plate s as required o AC to POE power supply o Cable s assembly o GPS antenna kit where applicable sold separately Tool Requirements For further information see Verify the Tool...

Page 35: ...r performing check off each task Procedure Action Check If Performed Verify the prerequisites Verify the site requirements Verify the installation requirements Verify the tool requirements Verify the parts kits required AirVelocity 1500 installation Assemble rail brackets on AirVelocity unit two 2 places Install the Ceiling mounting plate as required Install AirVelocity 1500 on the Ceiling mountin...

Page 36: ...oth very large and very small values in a short form eNodeB Evolved Node B is the element in E UTRAN of LTE FDD Frequency Division Duplexing A transceiver mode where the transmitter and receiver operate at different carrier frequencies IPSec Internet Protocol Security is a protocol suite for securing Internet Protocol IP communications by authenticating and encrypting each IP packet of a communica...