OPERATION

* Press the START/STOP button to start the air conditioner, and then proceed as

follows.

Press the VERTICAL AIRFLOW DIRECTION button to adjust the direction of the verti-
cal airflow. To set the swing operation, press the VERTICAL AIRFLOW DIRECTION
button for more than 2 seconds. (Stop the setting by pressing for more than 2 sec-
onds again.)

* Press the START/STOP button to start the air conditioner, and then proceed as

follows.

Press the HORIZONTAL AIRFLOW DIRECTION button to adjust the direction of the
horizontal airflow. To set the swing operation, press the HORIZONTAL AIRFLOW
DIRECTION button for more than 2 seconds. (Stop the setting by pressing for more
than 2 seconds again.)

● 

Horizontal air direction adjustment (Swing operation)

NOTES

(1) • Always use the remote controller’s AIRFLOW DIRECTION

button. Attempting to move the air direction louvers
manually could result in improper operation; in this case,
stop operation and restart.

The flaps should begin to operate properly again.

• During cooling operation, do not set the vertical airflow

direction louver in the downward position for an ex-
tended period. Water vapor may condense near the out-
let port and drops of water may drip from the air condi-
tioner.

(2) • The range of swing is relative to the currently set airflow

direction.

• The SWING operation may stop temporarily when the

air conditioner’s fan is not operating, or when operating
at very low speeds.

(3)

The swing operation is not available depending on the
model. Please refer to the operating manual for the in-
door unit.

<Vertical airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

3

2

2

 to 

4

3

2

 to 

4

4

1

 to 

4

 (All range)

1

2

3

4

<Horizontal airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

5

 (All range)

2

1

 to 

3

3

2

 to 

4

4

3

 to 

5

5

1

 to 

5

 (All range)

ex. Vertical swing operation

ex. Horizontal swing operation

To set the operation mode

● 

Vertical air direction adjustment (Swing operation)

1 2 3 4 5

Summary of Contents for UTB- UB

Page 1: ...PERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES Remote Controller UTB UB REMOTE CONTROLLER WIRED TYPE TM English Deutsch Fran ais E...

Page 2: ...d are most likely to result in the death of or serious injury to the user or service personnel Do not attempt to install this controller by yourself This controller contains no user serviceable parts...

Page 3: ...tting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 10 12 14 or 16 to 30 C Lower Raise Operation lamp Air conditioner ON Lit brightly Air conditioner OFF Not lit Press the START STOP button Press the...

Page 4: ...uld result in improper operation in this case stop operation and restart The flaps should begin to operate properly again During cooling operation do not set the vertical airflow direction louver in t...

Page 5: ...n is pushed Indoor unit ON OFF TIMER Instructions related to heating are applicable to HEAT PUMP MODELS and HEAT RECOVERY MODELS only The timer function is not available depending on the model To set...

Page 6: ...time setting Set the OFF time in the same way If necessary set the second weekly timer settings in the same way When the operating time is set the mark appears 6 Press the SET button for 2 seconds or...

Page 7: ...NOTES 1 PRECAUTIONS DURING WEEKLY TIMER SETUP Setup is not possible in the following cases so amend the time Be sure to set the ON time first then the OFF time If either the ON time or the OFF time i...

Page 8: ...SA 3 6 9 12 15 18 21 DAY OFF DAY 1 3 SET 2 SET 4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the SET TEMPERATURE buttons to set the temperature f...

Page 9: ...tion will be displayed on the remote controller Weekly timer Set different operating times for each day of the week Set one or two operating spans one or two ON times and one or two OFF times per day...

Reviews: