ERROR CODE DISPLAY

The air conditioning system must be inspected if “E

:

✽✽

” (error code) appears on the Timer and Clock Display, or the opera-

tion lamp is flashing. Stop air conditioner operation and please consult authorized service personnel.

OPERATING TIPS

Cooling/heating priority (AIRSTAGE

TM

(V-II Series Heat Pump model only))

If another indoor unit in the same system is already ope-
rating in the cooling mode or dry mode, heating mode set-
tings cannot be performed.

An indoor unit that is set up as an administrative indoor
unit can operate in the AUTO mode.
Administrative indoor unit:
Special indoor unit is not restricted by the switching of
cooling and heating described above.
It may happen if the unit is set to refrigerant system set-
ting.

TROUBLESHOOTING

Before requesting service, perform the following checks:

Symptom

Does not operate at all.

Items to check

Has there been a power failure?

Has a fuse of converter blown out, or a circuit breaker been tripped?

Is the main power switch set to the OFF position?

Is the timer operating?

CHECK ONCE

MORE

If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the
electrical breaker and consult authorized service personnel.

SPECIFICATIONS

GROUP REMOTE CONTROLLER (WIRED TYPE)

MODEL

POWER

DIMENSIONS & WEIGHT

HEIGHT

WIDTH

DEPTH

WEIGHT

UTY-CGG

DC 12 V

120 mm (4-3/4 in.)

120 mm (4-3/4 in.)

17 mm (5/8 in.)

160 g (0.35 lbs.)

MONITOR MODE

 The operation status of each indoor unit can be checked in the Monitor mode.

To enter the Monitor mode

After blinking as 

 (after transmission), it will switch to Monitor Mode

in 60 seconds automatically. When a key operation is in progress, 

 is

displayed. * 

 is not shown in the Monitor mode.

Press the Select button to select an indoor unit to display the current status.

Setting display

When a key operation is in progress, 

 is displayed.

After blinking as 

 (after transmission), it will switch to

Monitor Mode in 60 seconds automatically.
After the operation is complete, 

 flashes for a minute,

and then goes off.

When

 is flashing, it means that the signal is being

transmitted.  During this time, key operations are disabled.

When

 is displayed there are functions for which set-

tings cannot be made.

NOTES

(1) The WEEKLY timer does not operate when the HEAT timer is set if a HEAT PUMP MODEL in the air conditioning system

is operating in the cooling mode. In addition, the WEEKLY timer does not operate when the COOL or DRY timer is set if
a HEAT PUMP MODEL in the air conditioning system is operating in the heating mode.

(2) Even if the timer operation is set, the timer lamp of the indoor unit does not light up. (The timer lamp is used for

wireless remote controller only.)

(3) If the same time is set in Timer-1 to Timer-4 of an indoor unit, the timer setting of the smallest number will be effective.

 not shown

Summary of Contents for UTY-CGG

Page 1: ...FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGF LTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y R F RER UL...

Page 2: ...l for repairs When moving consult authorized service personnel for disconnection and installation of this unit Do not touch with wet hands It may cause an electric shock If children may approach the u...

Page 3: ...ton Set Temperature Button Child Lock Function Timer and Clock Display and setting Displaying the Status and Controlling indoor units Indoor Unit Operation Indicators This shows the operating status a...

Page 4: ...o 88 F HEAT 10 to 30 C 48 to 88 F The set temperature cannot be set during the FAN mode The temperature will not appear on the remote controller s display Raise Press the Set Temperature buttons to se...

Page 5: ...rwise you will en ter the time setting mode 2 Press the Select button to select the indoor unit If all indoor units are selected the times for all of the registered indoor unit timers are set at once...

Page 6: ...ing the ENTER button without any operation setting because the time that is set will be cancelled To delete the operating time WEEKLY TIMER Timer setting AM 8 When the operating time is set the mark a...

Page 7: ...ONS WEIGHT HEIGHT WIDTH DEPTH WEIGHT UTY CGG DC 12 V 120 mm 4 3 4 in 120 mm 4 3 4 in 17 mm 5 8 in 160 g 0 35 lbs MONITOR MODE The operation status of each indoor unit can be checked in the Monitor mod...

Page 8: ......

Reviews: