background image

En-7

* Microcomputer-controlled Automatic 

Defrosting

  When using the Heating mode under conditions of low outdoor 

temperature and high humidity, frost may form on the outdoor 
unit, resulting in reduced operating performance.

  In order to prevent this kind of reduced performance, this unit is 

equipped with a Microcomputer-controlled Automatic Defrosting 
function. If frost forms, the air conditioner will temporarily stop, 
and the defrosting circuit will operate briefl y (for about 4 to 15 
minutes).

  During Automatic Defrosting operation, the OPERATION indica-

tor lamp (green) will fl ash.

Low Ambient Cooling

 When the outdoor temperature drops, the outdoor unit’s fans 

may switch to Low Speed.

*Hot start (for heating)

 The indoor unit prevents cold drafts when heating operation 

begins.

  The indoor unit fan will not operate or it will operate at a very low 

speed until the heat exchanger reaches the set temperature. 

Mode operation: AUTO

COOLING MODEL

 When the room temperature is higher than the defi ned  tem-

perature in temperature setting, the mode will switch between 
Cooling and Drying.

HEAT PUMP MODEL

Auto changeover function

 When AUTO CHANGEOVER is selected, the air conditioner 

selects the appropriate operation mode (Cooling or Heating) 
according to your room’s present temperature.

 When AUTO CHANGEOVER is fi rst selected, the fan will 

operate at a very low speed for about 1 minute while the unit 
determines the current conditions of the room and selects the 
proper operation mode.

 

Room temperature is higher than the defi ned temperature in 
temperature setting 

 Cooling mode or Dry mode

 

Room temperature is close to the defi ned temperature in 
temperature setting 

 Determined by outdoor temperature

 

Room temperature is lower than the defi ned temperature in 
temperature setting 

 Heating mode

 During the Drying mode operation, the FAN setting should be 

switched to LOW for a gently cooling effect during which the 
fan may temporarily stop rotating.

Defi ned temper-
ature in tem-
perature setting

Cooling or Dry

Determined by out-
door temperature

Heating

 When the room temperature is near the temperature setting, 

the air conditioner will begin monitor operation. In the monitor 
operation mode, the fan will operate at a very low speed. If the 
room temperature subsequently changes, the air conditioner 
will once again select the appropriate operation (Heating or 
Cooling) to adjust the temperature to the value set in the in-
door unit. (The monitor operation range is ±2 °C relative to the 
temperature setting.)

About Mode Operation

*Heating:

 Use to warm your room.

 When Heating mode is selected, the air conditioner will 

operate at very low fan speed for about 3 to 5 minutes, after 
which it will switch to the selected fan setting. This period of 
time is provided to allow the indoor unit to warm up before 
beginning full operation.

  When the room temperature is very low, frost may form on the 

outside unit, and its performance may be reduced. In order 
to remove such frost, the unit will automatically enter the 
defrost cycle from time to time. During Automatic Defrosting 
operation, the OPERATION indicator Lamp (green) will fl ash, 
and the heat operation will be interrupted.

  After the start of heating operation, it takes sometime before 

the room gets warmer.

Cooling:

 Use to cool your room.

Dry:

 Use for gently cooling while dehumidifying your room.

 You cannot heat the room during Dry mode.

  During Dry mode, the unit will operate at low speed; in order 

to adjust room humidity, the indoor unit’s fan may stop from 
time to time. Also, the fan may operate at very low speed 
when adjusting room humidity.

  The fan speed cannot be changed manually when Dry mode 

has been selected.

Fan:

 Use to circulate the air throughout your room.

During Heating mode:

Set the temperature to a temperature setting that is higher than the 
current room temperature. The Heating mode will not operate if the 
preset temperature is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the temperature to a temperature setting that is lower than the cur-
rent room temperature. The Cooling and Dry modes will not operate if 
the preset temperature is set higher than the actual room temperature 
(in Cooling mode, the fan alone will operate).

During Fan mode:

You can not use the unit to heat and cool your room.

AUTO Restart

In Event of Power Interruption

 Should the power supply to the air conditioner be interrupted 

by a power failure, the air conditioner will restart automatically 
in the previously selected mode once the power is restored.

  Should a power failure occur during TIMER operation, the timer 

will be reset and the unit will begin (or stop) operating under 
the new timer setting. In this event, the TIMER indicator lamp 
(orange) will fl ash.

 Use of other electrical appliances (electric shaver, etc.) or 

nearby use of a wireless radio transmitter may cause the air 
conditioner to malfunction. In this event, temporarily disconnect 
the power supply plug, reconnect it, and then use the remote 
control unit to resume operation.

AMP Air Conditioning

www.ampair.co.uk | sales@ampair.co.uk

Summary of Contents for UTY-LNHG

Page 1: ...ENTO MANDO A DISTANCIA INAL MBRICO Conserve este manual para posibles consultas futuras MANUALE DI ISTRUZIONI UNIT DI CONTROLLO SENZA FILI Conservare questo manuale per consultazione futura MANUAL DE...

Page 2: ...ear this unit or place a heating apparatus nearby It may cause malfunction Do not expose this unit directly to water Doing so will cause trouble electric shock or heating Do not set flower vases or wa...

Page 3: ...to align the battery polarities correctly 3 Close the battery compartment lid 4 Press the RESET button Use the tip of a ball point pen or other small object to press the button Set the Current time 1...

Page 4: ...Set the Fan Speed Press the FAN button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About 3 seconds later the entire display will reappear When set to...

Page 5: ...r operation Each time the button is pressed the timer function changes in the following order CANCEL OFF ON PROGRAM OFF ON OFF ON The receiver unit control panel s TIMER Indicator Lamp orange will lig...

Page 6: ...s to indicate the temperature when SLEEP Timer was set During Heating operation Indoor unit When the SLEEP timer is set the temperature setting is auto matically lowered 1 C every 30 minutes When the...

Page 7: ...or to shipment Contact authorized service personnel to change the signal code The remote control unit resets to signal code A when the batteries in the remote control unit are replaced If you use a si...

Page 8: ...The monitor operation range is 2 C relative to the temperature setting About Mode Operation Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fa...

Page 9: ...internal parts to warm up During Heating operation if the room temperature rises above the temperature setting the fan of indoor unit starts and stops If you wish to warm the room further set the pre...