En-8

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to 
“HEAT PUMP MODEL”.

 WARNING

In the event of a malfunction (burning smell, etc.), immediately 
stop operation, disconnect the power supply plug or turn off 
the circuit breaker, and consult authorized service personnel. 
Merely turning off the unit’s power switch will not completely 
disconnect the unit from the power source. Always be sure to 
disconnect the power supply plug or turn off your circuit breaker 
to ensure that power is completely off.

Before requesting service, perform the following checks:

NORMAL FUNCTION

Doesn’t operate immediately:

 If the unit is stopped and then immediately started again, 

the compressor will not operate for about 3 minutes, in or-
der to prevent fuse blowouts.

 Whenever the power supply plug is disconnected and then 

reconnected to a power outlet, the protection circuit will op-
erate for about 3 minutes, preventing unit operation during 
that period.

Noise is heard:

 During operation and immediately after stopping the unit, 

the sound of water flowing in the air conditioner’s piping 
may be heard. Also, noise may be particularly noticeable for 
about 2 to 3 minutes after starting operation (sound of cool-
ant fl owing).

 During operation, a slight squeaking sound may be heard. 

This is the result of minute expansion and contraction of the 
front cover due to temperature changes.

*

  During Heating operation, a sizzling sound may be heard 

occasionally. This sound is produced by the Automatic De-
frosting operation. (See page 7)

Smells:

  Some smell may be emitted from the indoor unit. This smell 

is the result of room smells (furniture, tobacco, etc.) which 
have been taken into the air conditioner.

Mist or steam are emitted:

 During Cooling or Dry operation, a thin mist may be seen 

emitted from the indoor unit. This results from the sudden 
Cooling of room air by the air emitted from the air condi-
tioner, resulting in condensation and misting.

*

  During Heating operation, the outdoor unit’s fan may stop, 

and steam may be seen rising from the unit. This is due to 
the Automatic Defrosting operation. (See page 7)

Airfl ow is weak or stops:

*

  When Heating operation is started, fan speed is temporarily 

very low, to allow internal parts to warm up.

*

  During Heating operation, if the room temperature rises 

above the temperature setting, the fan of indoor unit starts 
and stops. If you wish to warm the room further, set the pre-
set temperature to a higher setting.

*

  During Heating operation, the unit will temporarily stop 

operation (between 4 and 15 minutes) as the Automatic 
Defrosting mode operates. During the Automatic Defrosting 
operation, the OPERATION indicator lamp (green) will fl ash. 
(See page 7)

 The fan may operate at very low speed during Dry opera-

tion or when the unit is monitoring the room’s temperature.

 In the monitor AUTO operation, the fan will operate at very 

low speed.

Water is produced from the outdoor unit:

*

  During Heating operation, water may be produced from the 

outdoor unit due to the Automatic Defrosting operation. (See 
page 7)

Instructions relating to heating (*) are applicable only to 
“HEAT PUMP MODEL”.

CHECK ONCE MORE

Doesn’t operate at all:

  Has the circuit breaker been turned off?

  Has there been a power failure?

  Has a fuse blown out, or a circuit breaker been tripped?

Poor Cooling (or Heating) performance:

  Is the timer operating? (See page 4 to 5)

  Is the air fi lter dirty?

  Are the air conditioner’s intake grille or outlet port blocked?

  Did you adjust the room temperature settings correctly?

  Is there a window or door open?

  In the case of Cooling operation, is a window allowing bright 

sunlight to enter? (Close the curtains.)

 In the case of Cooling operation, are there heating appara-

tus and computers inside the room, or are there too many 
people in the room?

The unit operates differently from the remote control unit’s 
setting:

  Are the remote control unit’s batteries dead? (See page 2)

  Are the remote control unit’s batteries loaded properly? (See 

page 2)

Signal is not received after replacing the batteries for the 
remote control unit:

  Are you using an air conditioner signal code other than sig-

nal code A? (See page 6)

If the problem persists after performing these checks, or if you 
notice burning smells, or the TIMER indicator lamp (orange) and 
OPERATION indicator lamp (green) fl ashes, stop operation im-
mediately, disconnect the power supply plug, and consult with 
authorized service personnel.

SPECIFICATIONS

REMOTE CONTROLLER (WIRELESS TYPE)

MODEL

UTY-LNH

POWER

DC 3 V

DIMENSIONS & 

WEIGHT

HEIGHT

170 mm

WIDTH

56 mm

DEPTH

19 mm

WEIGHT

85 g (w/o batteries)

AMP Air Conditioning

www.ampair.co.uk | sales@ampair.co.uk

Summary of Contents for UTY-LNHG

Page 1: ...ENTO MANDO A DISTANCIA INAL MBRICO Conserve este manual para posibles consultas futuras MANUALE DI ISTRUZIONI UNIT DI CONTROLLO SENZA FILI Conservare questo manuale per consultazione futura MANUAL DE...

Page 2: ...ear this unit or place a heating apparatus nearby It may cause malfunction Do not expose this unit directly to water Doing so will cause trouble electric shock or heating Do not set flower vases or wa...

Page 3: ...to align the battery polarities correctly 3 Close the battery compartment lid 4 Press the RESET button Use the tip of a ball point pen or other small object to press the button Set the Current time 1...

Page 4: ...Set the Fan Speed Press the FAN button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About 3 seconds later the entire display will reappear When set to...

Page 5: ...r operation Each time the button is pressed the timer function changes in the following order CANCEL OFF ON PROGRAM OFF ON OFF ON The receiver unit control panel s TIMER Indicator Lamp orange will lig...

Page 6: ...s to indicate the temperature when SLEEP Timer was set During Heating operation Indoor unit When the SLEEP timer is set the temperature setting is auto matically lowered 1 C every 30 minutes When the...

Page 7: ...or to shipment Contact authorized service personnel to change the signal code The remote control unit resets to signal code A when the batteries in the remote control unit are replaced If you use a si...

Page 8: ...The monitor operation range is 2 C relative to the temperature setting About Mode Operation Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fa...

Page 9: ...internal parts to warm up During Heating operation if the room temperature rises above the temperature setting the fan of indoor unit starts and stops If you wish to warm the room further set the pre...

Page 10: ...AMP Air Conditioning www ampair co uk sales ampair co uk...

Reviews: