5-14
NOTE
If warranty service is required, use only a
service location recommended by the furnace
manufacturer or your Airstream dealer.
Ducted Roof System
Flying Cloud models are designed with a ducted roof
system. This system provides a more efficient air flow
throughout the trailer and allows equal air to be blown
from each vent� The ducted roof helps to create a more
balanced temperature inside the trailer�
Microwave Ovens
Refer to the Certified Performance Checkout sheet,
included in your owner’s packet, for manufacturer,
model, and serial number information�
Range
There is little difference between the operation of home
gas ranges and the trailer’s range� If, however, you are
used to an electric range, operating confidence can be
quickly gained by reading the manufacturer’s directions
provided in the owner’s packet� Manufacturer’s service
and parts manuals are also available�
WARNING
An operation manual for the range has been
provided with your owner’s packet. If this has not
been provided with your trailer, contact the listed
manufacturer to obtain. Their manual contains
specialized warnings and cautions that should be
reviewed prior to operating the appliance.
Refrigerator
Review all refrigerator literature supplied in your
owner’s packet or stored in the refrigerator prior to
operating�
In an absorption refrigerant system, ammonia is
liquefied in the finned condenser coil at the top-rear of
the refrigerator. The liquid ammonia then flows into the
evaporator (inside the freezer section) and is exposed
to a circulating flow of hydrogen gas, which causes the
ammonia to evaporate, creating a cold condition in the
freezer�
The tubing in the evaporator section is specifically
sloped to provide a continuous movement of liquid
ammonia, flowing downward by gravity, through this
section� If the refrigerator is operated out-of-level
when the vehicle is not moving, liquid ammonia will
accumulate in portions of the evaporator tubing� This
Thermostat and Rain Sensor
The fan is equipped with a built-in thermostat� Select
your comfort setting and the fan will automatically turn
on and off as your trailer heats up and cools down�
When the rain sensor becomes wet the dome will close
automatically and shut the fan off� Once the sensor has
dried out the dome will reopen and the fan will restart�
1� Follow the previous operation steps one through
three�
2� Select the desired temperature or comfort level
using the thermostats knob� The fan motor will
now start and stop automatically as the interior
temperature of the trailer exceeds or drops below
the selected level�
NOTE
Fan motor will not start if temperature selected is
warmer than interior temperature of the trailer.
Cleaning Instructions
1� Turn fan motor off�
2� Remove the screws around perimeter of screen
insert only�
3� Clean screen with soap and water solution, dab dry
with a soft cloth, and reinstall�
CAUTION
This product has been manufactured using prime
UV stabilized Polymers for maximum toughness
and durability. However, the use of non-compatible
chemicals will cause cracking and product failure.
Please refer to the user’s manual provided in your
owner’s packet for more information.
Furnace
The manufacturer of the furnace in your trailer has
been well known in the RV industry for many years�
The furnace burns LP gas, and is powered by 12-volt
current from the batteries or power converter when
plugged into city power� Operating instructions are
located in your Owners Packet� If they should become
misplaced, new literature can be ordered direct
from the manufacturer or your Airstream dealer� The
manufacturer also offers a detailed service guide for
your furnace�
WARNING
Carefully read all the manufacturer’s instructions
prior to operating. NEVER store flammable material
next to the furnace or in close proximity to the
furnace exhaust outlet on the side if the trailer.
Summary of Contents for Flying Cloud 2020
Page 1: ...2020 Flying Cloud Owner s Manual...
Page 4: ...2020 Flying Cloud NOTES...
Page 6: ...2020 Flying Cloud 1 2 Introduction NOTES...
Page 26: ...2020 Flying Cloud 3 14 General Information NOTES...
Page 32: ...2020 Flying Cloud 4 6 Floor Plans And Specifications NOTES...
Page 50: ...2020 Flying Cloud 5 18 Interior NOTES...
Page 60: ...2020 Flying Cloud 6 10 Exterior NOTES...
Page 85: ...Maintenance 2020 Flying Cloud 8 17 22 22 Electrical Diagrams 12 Volt Main Schematic...
Page 102: ...Maintenance 8 34 2020 Flying Cloud Fresh Water Layouts Fresh Water Layout 23CB Flying Cloud...
Page 103: ...Maintenance 2020 Flying Cloud 8 35 Fresh Water Layout 23FB Flying Cloud...
Page 104: ...Maintenance 8 36 2020 Flying Cloud Fresh Water Layout 25RB Flying Cloud...
Page 105: ...Maintenance 2020 Flying Cloud 8 37 Fresh Water Layout 25FB Flying Cloud...
Page 106: ...Maintenance 8 38 2020 Flying Cloud Fresh Water Layout 26 Flying Cloud...
Page 107: ...Maintenance 2020 Flying Cloud 8 39 Fresh Water Layout 27FB Flying Cloud...
Page 108: ...Maintenance 8 40 2020 Flying Cloud Fresh Water Layout 28 Flying Cloud...
Page 109: ...Maintenance 2020 Flying Cloud 8 41 Fresh Water Layout 30 Flying Cloud...
Page 110: ...Maintenance 8 42 2020 Flying Cloud Fresh Water Layout 30 Bunk Flying Cloud...
Page 114: ...2020 Flying Cloud 8 46 Maintenance NOTES...
Page 117: ......