Manual Configuration of SpectraGuard Sensor
SpectraGuard Sensor Installation Guide
23
The default gateway
—
When Ethernet traffic from the subnet is forwarded to another network,
it is sent through the Gateway. Enter the Gateway IP Address for the subnet on which this
SpectraGuard Sensor is to be connected.
Route Settings
—
Normally, you do not need to specify the route settings. You should specify the
route settings only if the default gateway provided by the DHCP Server is not the gateway to the
network segment where SpectraGuard Enterprise Server is installed.
Network ID
—
This specifies the network segment ID, where the SpectraGuard Enterprise
Server is connected. (E.g.: 192.168.5.0)
Subnet Mask
—
This represents the mask of the network segment where the SpectraGuard
Enterprise Server is connected. (E.g.: 255.255.255.0)
Gateway
—
This is the IP address of the gateway to the network segment where the
SpectraGuard Enterprise Server is connected. (E.g.: 192.168.3.250)
Note:
You can retain the default values for the above inputs by pressing
Enter
.
Type the following commands (shown in bold) to change the IP and Route Settings for the
SpectraGuard Sensor.
The following screen is an example from a live session.
$ setstaticip
Current Settings are:
IP=192.168.3.33 Mask=255.255.255.0 Gateway=192.168.3.254
Enter new addresses or Enter to leave unchanged
IP:
192.168.3.33
Setting IP to 192.168.3.33
Mask:
255.255.255.0
Setting Mask to 255.255.255.0
Gateway:
192.168.3.254
Setting Gateway to 192.168.3.254
Enter Route Settings or press Enter to skip setting routes
Route Settings:
Network ID:
Applying Changes...
Stopping SpectraGuard Sensor...
Ethernet MAC Address = 00:11:74:20:10: C4
Boot IP Protocol = static
IP=192.168.3.33 Mask=255.255.255.0 Gateway=192.168.3.254
Starting SpectraGuard Sensor...