Mounting to a Wall 

After deciding where to mount the clock, make two marks 12" apart 

and horizontal.  

Note: If mounting near a ceiling, make sure the holes 

are at least 2 1/4" away from the ceiling.  Also, provide at least 16" of 

side clearance on one side in order to remove the front panel. 

 

Installation Steps 

1.

 

Drill a 5/16" hole at each mark 

2.

 

Insert a wall anchor and tap it flush to the wall with the hammer. 

3.

 

Insert a screw into each wall anchor leaving 1/4" exposed. 

4.

 

Line up the two keyholes on the back of the case and slip over the 
two screws and tighten securely. ( The lower mounting holes can 

be marked at this point, the case removed, holes drilled and wall 
anchors installed if so desired) 

Mounting to a Single Gang Box 

Two mounting holes are located in the center of the case 2 1/4" apart 

for mounting to a single gang wall box. A 7/8" hole is located between 
the mounting holes that will accommodate conduit, if desired. 

 

Note: If mounting near a ceiling, make sure the holes are at least 2- 

1/4" away from the ceiling.  Also, provide at least 16" of side clearance 
on one side in order to remove the front panel. 

 
Line the two holes in the case up to the single gang box and insert 

proper screws for the single gang box and tighten securely. 

 

 

ATDDC4 Series Installation & User’s Guide 

Page 9 

 

Double Mount - Ceiling 

Requires optional mounting kit (SAM0626) 

 

Double-Mounting - Ceiling 

Note: Make sure you have at least 16" of side clearance on one side in 
order to remove the front panel assembly. 

 

1.

 

Place the two clock enclosures back to back and secure by inserting 
a #10 screw through the four mounting holes using lock washers 

and nuts supplied with the mounting kit. 

2.

 

Note: If the ATDDC4 clocks will be mounted too near a wall on one 

side to secure the end caps, install the "wall side" end caps now.

 

3.

 

Remove the center vent cap from the top of each ATDDC4 clock. 

4.

 

Line the two posts from the mounting plate up with the vent holes 
of the ATDDC4 clocks. Insert the chase nipples through the vent 

holes and secure to the mounting plate with a 15/16" wrench.

 

 

Summary of Contents for ATDDC4

Page 1: ...Wireless Digital Wall Clock Model ATDDC4 Installation User s Guide...

Page 2: ...nected Consult the dealer or an experienced radio TV technician for help This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be i...

Page 3: ...athem be liable for any direct indirect special incidental or consequential damages arising out of or in connection with the delivery use or inability to use or performance of this product In the even...

Page 4: ...Military style 12 Hour Format AM PM 24 Hour Format AM PM ATDDC4 Series Installation User s Guide Page 11 Specifications Dimensions 6 3 4 H X 15 1 2 W X 3 1 8 D 17 1 cm H X 39 cm W X 7 9 cm D Weight 9...

Page 5: ...ion User s Guide Page 3 To set the display format use the jumper J1 located on the back of the circuit board which can be accessed by removing the right side end cap and sliding the circuit board out...

Page 6: ...ommodate conduit if desired Note If mounting near a ceiling make sure the holes are at least 2 1 4 away from the ceiling Also provide at least 16 of side clearance on one side in order to remove the f...

Page 7: ...ble from the bottom Note Optional plastic end panels may be ordered left VIS1551 L right VIS1551 R that have access holes pre drilled for side access Power Cord Installation The optional AC Power Cord...

Page 8: ...wo Phillips head screws 3 When the clock is energized it will set itself upon receiving the AirTime radio signal ATDDC4 Series Installation User s Guide Page 7 Double Mount Wall The ATDDC4 SERIES requ...