background image

 

7.

 

Attach hood cover inside cupboard (Fig 10). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig 10 

 

3.2 Electrical Wiring

 

 
The  electrical  wiring  must  be  performed  by  a 
specialised  electrician  fully  respecting  current 
standards  and  legislation  in  force.  Check  that  the 
power supply corresponds to the voltage requested 
by the hood, which is given on the silver label stuck 
inside  the  hood.  
Ensure  that  the  wiring  system 
conforms  to  current  standards  and  the  earth 
discharge  works  efficiently.  Pay  special  attention  to 
the  hood  power  cable,  ensure  that  it  does  not  pass 
through any holes without a  cable clamp. For direct 
connection  to  the  electrical  mains  it  is  necessary  to 
provide a device that ensures disconnection from the 
electrical  mains,  with  an  opening  distance  of  the 
contacts  that  allows  the  complete  disconnection 
under  the  conditions  of  overvoltage  category  III,  in 
accordance with the rules of installation. The plug or 
Omni polar switch must be accessible when the unit is 
installed. 
If the power cord is damaged, it must be replaced by 
a  special  cord  or  assembly  available  from  the 
manufacturer or its service agent. The cable must be 
of type H05VV-F 3 x 0.75mm

2

 minimum cross-section. 

 
The  manufacturer  declines  all  responsibility  if  the 
current  accident  prevention  standards  in  force  are 
not  respected,  which  are  needed  for  the  wiring 
system to operate correctly.
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Aida 60

Page 1: ...1 Aida 60 90 Built In Cupboard Hood Installation User Instructions Please read these instructions carefully before installing and operating this appliance ...

Page 2: ... Electrical Wiring 6 8 3 2 1 Electrical Wiring Diagram 7 3 2 2 Controls 8 4 Use Maintenance 8 9 4 1 Changing the Light Bulbs 8 4 2 Cleaning the Metal Filters 8 4 3 Carbon Filters 9 4 3 1 Polyester Carbon Filters 9 4 3 2 Long Life Carbon Filters 9 4 4 Cleaning the Hood 9 5 Technical Data 9 6 Dimensions 10 ...

Page 3: ...a region and country For the correct use of the appliance and to prevent accidents the instructions given in this booklet must always be followed Before beginning any operation the user or whoever is preparing to operate on the appliance must have read and understood the entire contents of this instruction booklet All responsibility for improper use is taken entirely by the user and as such reliev...

Page 4: ...use a fire hazard ATTENTION Accessible parts may become hot when the hood is used with cooking appliance 3 Installation The minimum safety distance between the bottom of the hood and the top of the cooking hob must be 650mm Fig 1 smaller distances must be previously authorised by the manufacturer Ø150mm round or 220x90mm rectangular ducting must be used Ducting with a smaller diameter could cause ...

Page 5: ... Cut the rectangular ducting down to size Fig 6 Fig 6 3 Attach the ducting to the hood section Fig 7 Fig 7 4 Push hood and ducting up into cupboard and connect to motor Fig 8 Fig 8 5 Adjust metal sliders and tighten bolt to hold hood in cupboard Fig 9 Fig 9 6 Connect motor cable to control box cable ...

Page 6: ... direct connection to the electrical mains it is necessary to provide a device that ensures disconnection from the electrical mains with an opening distance of the contacts that allows the complete disconnection under the conditions of overvoltage category III in accordance with the rules of installation The plug or Omni polar switch must be accessible when the unit is installed If the power cord ...

Page 7: ...7 3 2 1 Electrical Wiring Diagram To motor plug Supply Blue Grey White Black Red Blue Brown Blue Brown To control buttons on hood To light transformer ...

Page 8: ...or maintenance work turn the power off to the hood by turning the main switch to 0 OFF 4 1 Changing the Light Bulbs 12V halogen G4 attachment Use a screwdriver to unscrew the glass support ring Fig 12 23 Remove the glass and change the light bulb Replace the protective glass and screw back the ring The light bulbs can be purchased in any electrical supply shop Fig 12 Fig 13 Dichroic lamp G4 attach...

Page 9: ...anged when it no longer absorbs the cooking smells sufficiently Fig 24 4 4 Cleaning the Hood The surfaces of the hood should be cleaned frequently to avoid the risk of having to remove built up and encrusted deposits and stains For the painted or copper plated hoods just a soft cloth with warm water and a neutral detergent Do not pour the detergent directly onto the hood or use powdery or abrasive...

Page 10: ...10 6 Dimensions 420 250 260 265 660 230 1000 58 ...

Page 11: ...11 ...

Page 12: ... of all contents of this leaflet is vested in CD UK Ltd t a Air Uno Any part may not be reproduced without permission The contents of this leaflet are accurate at the date of printing but because CD UK Ltd t a Air Uno has a policy of continual development it may be superseded and should be disregarded if specifications or appearances are changed The statutory rights of the customer are not affecte...

Reviews: