CONTROL SYSTEM
11-23
SM TELECOM 1-A.0 GB
11.11.2 DRY, SH or RH group
Mode: DRY
Temp: Selected desired temperature
Fan:
LOW (automatically selected by software)
Timer: Any
I-FEEL: Any
Control function
Reduces room humidity with minimum temp. fluctuations by operating in Cool Mode
with LOW speed IFAN and HE.
(RT - SPT) [
o
c]
+2
+1
0
-1
-2
ON
OFF
ON
OFF
LOW
OFF
ON
OFF
10
20
30
40
50
COMP
& OFAN
HE1
IFAN
HE2
ON
OFF
RV
Time [min]
CONTENTS