CONTROL SYSTEM
11-29
SM TELECOM 1-A.0 GB
11.12.3
Condensation Pump (ECC/K model)
Mode: Cool, Dry, Auto
Temp: Selected desired temperature
Fan: Any
Timer: Any
I FEEL:
Any
Control function:
Prevent Condensed water from Overflowing.
ON
OFF
ON
COMP
(WVL)
PUMP
OFF
ON
OPER
LED
OFF
Overflow
Water Level
Normal
BLINK
COMP/WVL is
forced OFF
8 min
8 min
Overflow when
unit is ON
Overflow when
unit is OFF
1 min
Notes:
1. The switch used for water level detection is closed under normal condition, and is open
when water overflow.
2. For the NEC version of MCU, the "Over Flow" & “Normal” condition are indicated by
logic “0” & “1” at the LEVEL4 input pin respectively.
3. For the Fujitsu version of MCU, the "Over Flow" & “Normal” condition are indicated by
logic “1” & “0” at the LEVEL4 input pin respectively.
4. The “Overflow” condition can activate the water pump in SB and operating modes.
CONTENTS