5-3
PERFORMANCE DATA
SM TQDCI 1-A.1 GB
5.1.3 Heating
Model
Heating Capacity [KW]
Power Consumption
[W]
COP
Nom.
Energy
Efficiency
Class
A
B
C
Nom.
Min.
Max. Nom.
Min.
Max.
9
-
-
3.40
3.40
0.95
4.00
685
500
897
4.96
A
12
-
-
4.30
4.30
0.95
5.20
1,003
485
1,320
4.29
A
18
-
-
6.20
6.20
1.11
7.50
1,673
549
2,131
3.71
A
9+9
-
3.60 3.60
7.20
1.43
9.10
1,883
649
2,636
3.82
A
9+12
-
3.26 4.34
7.60
1.43
9.50
2,009
649
2,711
3.78
A
9+18
-
3.00 6.00
9.00
1.43
10.10 2,451
622
2,737
3.67
A
12+12
-
4.00 4.00
8.00
1.43
9.80
2,135
649
2,711
3.75
A
12+18
-
3.60 5.40
9.00
1.43
10.50 2,451
622
2,871
3.67
A
9+9+9
3.00 3.00 3.00
9.00
2.06
10.99
2,370
804
3,013
3.80
A
9+9+12
2.70 2.70 3.60
9.00
2.06
11.00 2,370
804
2,966
3.80
A
9+9+18
2.25 2.25 4.50
9.00
2.06
11.00 2,370
773
2,826
3.80
A
12+12+12
2.45 3.27 3.27
8.99
2.06
11.00 2,367
804
2,938
3.80
A
9+12+18
2.07 2.76 4.14
8.98
2.14
11.00 2,365
773
2,752
3.80
A
12+12+12
3.00 3.00 3.00
9.00
2.06
11.00 2,370
804
2,845
3.80
A
12+12+18
2.57 2.57 3.85
8.99
2.14
11.00 2,367
773
2,696
3.80
A
Nominal Indoor Units Combination