Starting procedure for Twister unit:
1.
Compressor, generator and welder switches are in the off position (if equipped).
2.
Turn key switch counter clockwise (left) to activate intake heater, hold for a minimum of 20
seconds and a maximum of 45 seconds (varies with outside temperature).
3.
Turn key fully clockwise to crank position and hold till engine starts (maximum 20 seconds),
release key when engine starts.
(a)
Repeat steps 2 and 3 if engine does not start. If it fails to start after 3 attempts see
operation manual trouble shooting guide.
4.
Allow engine to idle until operating temperature is reached.
5.
Engage required function compressor, generator, welder or any combination of these (if
equipped).
Twister is now ready to operate.
Shutdown procedure:
1.
Ensure compressor, generator or welder (if equipped) is not under load before shutting down.
2.
Switch compressor, generator and welder (if equipped) master switches to off position.
3.
Allow twister to idle for 1 minute.
4.
Turn key switch to off (center) position.
Safety note:
Remove key before performing any maintenance on unit to prevent accidental starting. Do
not operate with covers removed.
For technical support call: 780-454-2263