Battery replacement
The Airzone Think Controller will display a battery alert on its screen when the batteries of the radio interfaces are low.
To replace the battery, please remove the controller from its back plate and then replace the battery (CR2450).
Important
: We recommend the use of top-brand batteries. Using low-quality batteries may reduce the duration of use.
ADVANCED USE OF THE THINK CONTROLLER
Setting Parameters
Press the Setting Menu icon to access the parameters.
Operation Mode.
This parameter is only available when the controller is configured as main, the available modes are:
Cool.
The conditioning unit will start a cooling cycle any time that any zone is in cool demand (T
Set-Point
< T
room
).
It enables to activate the heat supply function.
Heat.
Enables the heating cycle whenever a zone is in heating demand (T
Set-Point
> T
room
).
Auto.
The Auto mode allows automatic switching between cool and heat, depending on the global demand.
Dry.
In this mode, the air-conditioning unit will start a dehumidification cooling cycle any time that any zone is
under demand (T
Set-Point
< T
room
).
Note
: Dry mode decreases humidity in the room by entering the dehumidification cooling cycle.
Emergency Heat.
This mode activates the Auxiliary Heat to provide heated air in case of a mechanical failure in the
system.
Note:
This mode is only visible when the installation includes an auxiliary heating device.
Heat supply.
If the zone has an air supply stage configured, it allows to enable the Heat supply function in the selected zone
when the mode is set to Cool mode.
Note:
The heat supply function is only available for individual zone modules
User Mode.
This parameter is only available when the controller is configured as main, the available modes are:
Comfort.
Default and standard user mode. The desired set point temperature can be selected using the predefined
temperature ranges.
Eco.
The range of available set point temperatures adapts for getting a more efficient operation.
Night time.
The system automatically changes the set point temperature 0.5˚ C/1˚ F every 30 minutes in up to 4
increments of 2˚ C/4˚ F in 2 hours. When cooling, the system increases the set point temperature; when heating,
the system decreases the set point temperature.