Another cause of installation problems is incorrect parameter setting. This can be avoided by
writing down were each Zone Control Module is located and how are they configured (mainly
Zone Control Module addresses, and master-subordinate relationships).
5.1 Preparing the cables for wiring
All wires that will end in a connector should be prepared as shown below
Fig.1
If the cable will end inside the thermostat base, then this is the recommendation to prepare the
cable:
Fig. 2
Notice that when the cable ends at the thermostat base, the shield wire must be cut down, and
the shield itself should finish outside of the thermostat base. It is important to follow this
recommendation to avoid installation problems related to electrical noise.
3 in
1½ in
¼ in
¼ in