Linked zones
(only if there are previously configured secondary)
If necessary, the system allows you to associate more than one control output to a zone. It is possible to control multiple outputs
from the same controller.
Important:
You must select the zone/s that you want to configure as secondary outputs before pressing "Confirm".
Controller settings
Select the operation of the controller:
-
Main: Controls all the parameters of the installation.
-
Zone: Controls all the parameters of the zone.
Control stages
(only for installations with relay radiant heat control module)
Select stages to be controlled:
•
Heating: Air, Radiant or Air+Radiant.
•
Cooling: Air
It should be configured the type of unit installed for each stage:
•
Air: Direct Expansion or water Fancoil unit
•
Radiant: Electric, water or Air Supply unit
Main ID
(only if the controller has been previously configured as zone)
Select the main controller zone ID associated to the controller. Thus, this main controller will impose the operation mode to
the controller.
Other settings
Press to conclude the initial setup procedure or access the advanced settings to change any other settings. Activate the basic
function if required (see
Blueface