Access the main screen by pressing "Airzone" from the screensaver:
Local Ventilation
Main screen/
confirm
Communication frequency:
- 868.12 MHz (CEE)
- 915.2 MHz (EEUU, Canada, Australia, New Zeland)
Maximum radiated power: 0 dBm
On/Off.
Press to turn the zone On/Off.
Adjusting the temperature
23°
Temperature Control.
The temperature displayed on the screen is the current set point
temperature. Adjust the set point temperature on the Think Thermostat following the next
instructions:
Select the set point temperature using the control bar (by pressing or by sliding) to manually
adjust by increments of 0,5º C (1 ºF). Press once to adjust the set point temperature by
increments of 0,5º C (1 ºF). Slide to adjust the set point temperature in larger steps.
he permitted temperature range is:
•
Heating Mode: 15 ºC – 29 ºC (59 - 84 °F).
•
Cooling Mode: 18 ºC – 30 ºC (59 - 86 °F).
Note:
Press the Airzone button to switch between heat and cool set point temperatures.
There is a minimum difference allowed between heating and cooling set point temperatures.
The system will prevent setting a temperature within the protection range.
Configuration Menu
Local Ventilation.
This option enables the activation or deactivation of the ventilation
in the selected zone when the system is not actively cooling or heating any of the zones.
Important:
In Heat Pump installations, it is recommended not to activate the global and local
ventilation in an Airzone system connected to the master indoor unit. It may cause the Stop
user mode to turn off the rest of the Airzone system.