4
EN
Auto.
The Auto mode allows automatic switching between cool and heat, depending on the
global demand.
On/Off.
Pressing the icon turns the zone in which the thermostat is located on or off.
Cooling.
In this operation mode, the system only operates with the AC unit in cooling mode
when any of the zones associated to the system is generating demand (set-point temp. < room
temp.).
Heating.
In this operation mode, the system only operates with the AC unit in heating mode
when any of the zones associated to the system is generating demand (set-point temp. > room
temp.).
Dry*.
In this operation mode, the system only operates with the AC unit in dry mode,
refreshing the environment and prioritizing the operation to reduce humidity, when any of the
zones is generating demand (set-point temp. < room temp.).
*
Note
:
This mode is ideal for days when humidity is high: it reduces the occurrence of water
particles on the grilles.
This is managed from the master thermostat, press to access the selection menu. The available
modes are as follows:
HVAC control
Operation mode
23.5°
Set-point temperature.
Using the - and + signs that appear when you press on the
temperature, you can select the desired set-point temperature, in steps of 0.5°C (1 °F).
The temperature range permitted in heating mode is: 15-29 °C (59 - 84 °F). In cooling mode:
18-30°C (64 - 86 °F). These vary depending on the level of efficiency (Eco-Adapt) that has been
selected on the master interface.
Emergency Heat*.
This mode activates the Auxiliary Heat to provide heated air in case of a
mechanical failure in the system.
*Note:
This mode is only visible when the installation includes an auxiliary heating device.
User Mode
This option is only available in the Blueface Thermostat.
Comfort.
Default and standard user mode. The desired set point temperature can be
selected using the predefined temperature ranges.
Eco.
The range of available set point temperatures change for more efficient operation.
Night time.
The system automatically changes the set point temperature 0.5 ºC (1 ºF) every
30 minutes in up to 2 ºC (4 ºF) in 2 hours. When cooling, the system increases the set point
temperature; when heating, the system decreases the set point temperature.
Unoccupied.
To be used when there is no presence detected for short periods of time. A
more efficient set point temperature will be set. If the thermostat is activated, the zone will
start running in comfort mode.
Vacation.
This mode feature saves energy while the user is away for extended periods of
time.
Stop.
The air-conditioning system will remain switched off regardless of the demand status
of any zone, all the motorized dampers will remain opened.
Summary of Contents for ZS6
Page 1: ...User s Manual Easyzone ZS6 S62 ES EN FR...
Page 24: ......