Replacement of the Metal Halide Lamp
Always use the original IT Concepts 24W Metal Halide
Lamp (Art.Nr.: 900-01002-0004). Switch off the iTool
and the light source (Switch to position 0).
Before opening the light source always remove the
power supply cable from the iTool – High Voltage!
Wait at least 3 minutes until the lamp has cooled
down. Open the cover on the front of the light source
by releasing the two cross-drive screws.
Pull out the cover of the lamp socket until the plug of
the metal halide lamp is visible. Remove the plug from
the defective metal halide lamp and move the lamp
sideways off the socket. At this mind the nib on the
ceramic ring.
Maintenance
Caution!
Do not touch Reflection Surface of new Lamp
I = ein
0 = aus
1
2
3
cut power supply
wait 3 min.
release screws