8. Software Update
Devices, which are connected via RS-232 resp. RS-232/USB-Adapter
►
For a software update it is necessary that the program M16START.EXE is
installed and the file extension „MOT“ is linked to this program.
►
The
black
9-pin Sub-D plug on the communication cable must be connected to
COM1 of the PC.
►
The flat connector of the communication cable has to be connected to the
MDE device, respectively the MDE device
has to be put into the docking
station.
►
After double clicking the system software data file 01005
vvv
.MOT (contains
system and application software)
or
the application data file 03000
vvv
.MOT
(contains only application software) the program M16START.EXE will be
started.
►
If the download don’t start automatically: Release a software reset by pressing
button
SHIFT ESC
2 times or release a hardware reset (refer to chapter
System Functions/Hardware Reset
). After that M16Start will start the
software update.
►
If M16Start shows the error message „
Bad Security Key!
“ menu function
Security/Key Input
must be selected and the key
8602
must be entered
to force M16Start to start the software update. After that a hardware reset must
be released.
►
Confirm the data transfer notified end from M16START by pressing
ENTER
.
M16START is then closed automatically.
Devices, which are connected directly via USB (i.e. LogiScan-1100)
►
For a software update it is required that the programs MTWIN4.EXE and
M16Start.EXE are installed and MTWIN-4 was startet.
►
The device has to be connected to the PC with the appropriate USB cable.
►
After execution of MTWIN-4 menu function „Software Update“ and selection of
the desired MOT file M16Start will be called and the download starts usually
automatically.
►
If the download don’t start automatically: Release a software reset by pressing
button
SHIFT ESC
2 times or release a hardware reset (refer to chapter
System Functions/Hardware Reset
). After that M16Start will start the
software update.
►
If M16Start shows the error message „
Bad Security Key!
“ menu function
Security/Key Input
must be selected and the key
8602
must be entered
to force M16Start to start the software update. After that a hardware reset must
be released.
►
After the download is terminated M16START closes automatically.