<MW/LW Adjustment>
Make sure that the following settings are done before adjustment.
Preparation
*
Measuring instruments:
Standard Signal Generator (S.S.G.) / Loop antenna / Oscilloscope / Millivoltmeter / Dummy resistor (6
Ω
)
(1) Connect the measuring instruments as shown in the diagram below.
(2) Keep a distance of 60cm between the loop antenna of signal generator and the one connected to the unit.
5. IF Adjustment (MW)
Requirements
*
Test point: SP OUT (Lch, Rch)
Adjustment point: L802
(1) Adjust the S.S.G. setting to MW; carrier at 999 kHz with 30% modulation, and source at 1 kHz, position output at maximum.
(2) Adjust the unit to MW 999 kHz.
(3) While monitoring the 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the waveform).
(4) Adjust L802 so that the millivoltmeter indicates maximum.
6. Tracking Adjustment (MW)
Requirements: Same as Item 5.
*
Adjustment point: L952 / L953
(1) Adjust the S.S.G. setting to AM; carrier at 999 kHz with 30% modulation, and source at 1 kHz, position output at maximum.
(2) Adjust the unit to MW 999 kHz.
(3) While monitoring the 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the waveform.)
(4) Adjust L952 so that the millivoltmeter indicates maximum.
(5) Adjust the S.S.G setting to AM; carrier at 603 kHz; distortion rate at 30 %, and source at 1 kHz.
(6) Adjust the unit to MW 603 kHz.
(7) Adjust L953 so that the millivoltmeter indicates maximum.
(8) Repeat above steps (1) to (7) two or three times.
7. Tracking Adjustment (LW)
Requirements: Same as Item 5.
*
Adjustment point: TC942 / L941
(1) Adjust TC942 to the mechanical center.
(2) Adjust the S.S.G. setting to AM; carrier at 144 kHz with 30% modulation, and source at 1 kHz, position output at maximum.
(3) Adjust the unit to LW 144 kHz.
(4) While monitoring 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the waveform).
(5) Adjust L941 so that the millivoltmeter indicates the maximum level.
(6) Adjust the S.S.G setting to AM; carrier at 290 kHz; distortion rate at 30 %, and source at 1 kHz.
(7) Adjust the unit to LW 290 kHz.
(8) Adjust TC942 so that the millivoltmeter indicates the maximum level.
(9) Repeat the above steps (2) to (8) two or three times.
ELECTRICAL ADJUSTMENT -3/7
Summary of Contents for NSX-R17
Page 25: ... 25 SCHEMATIC DIAGRAM 3 5 HP SECTION TO MAIN C B 1 2 AMP SECTION WH101 ...
Page 30: ... 30 SCHEMATIC DIAGRAM 5 5 PT SECTION TO MAIN C B 1 2 AMP SECTION WH001 ...
Page 40: ... 40 FL DISPLAY 1 1 HUA 13SS09T GRID ASSIGNMENT ANODE CONNECTION PINCONNECTION ...
Page 41: ... 41 IC BLOCK DIAGRAM 1 2 IC LC72131D N IC BD3881FV ...
Page 42: ... 42 IC BLOCK DIAGRAM 2 2 IC LA1845N A ...
Page 53: ...2 11 IKENOHATA 1 CHOME TAITO KU TOKYO 110 8710 JAPAN TEL 03 3827 3111 0251431 ...