-39-
<FRONT Section>
20. Clock Adjustment
Requirements
•
Measuring instrument: Frequency counter
Test point: CLOCK, GND
Adjustment point: L951
1) While pressing the UP and POWER button,
insert the AC plug to the outlet.
2) Adjust L951 so that the frequency counter indicates the
frequency level within 72.743
±
0.073 Hz.
ELECTRICAL ADJUSTMENT -7/7
FRONT C.B PATTERN SIDE
FRONT C.B PARTS SIDE
GND
L951
CLOCK
20
20