17. Record/Playback Frequency Response Characteristics Adjustment (DECK2)
Conditions
Measuring equipment: Milli-volt meter
Audio signal generator
(Low frequency oscillator)
Attenuator
Test tape: TTA-602 (NORMAL)
Test point: TP8 (L-ch), TP9 (R-ch)
Input point: AUX (1 kHz/8 kHz)
Adjustment point: SFR451 (L-ch), SFR452 (R-ch)
1) Connect a milli-voltmeter CH1 to TP8 (L-ch) and CH2 to TP9 (R-ch).
2) Connect an oscillator output to an attenuator. Connect an attenuator output to AUX of the NSX-R90.
3) Insert the test tape (TTA-602) into DECK2 and record the 1 kHz signal from AUX.
4) Adjust the attenuator so that TP8 and TP9 output level become 10 mV.
5) Record the 1 kHz signal and 8 kHz signal alternately.
6) Adjust SFR451 (L-ch) and SFR452 (R-ch) so that the 8 kHz playback output level is within 0 +/- 1dB with respect to the 1 kHz output level that
is the reference output.
18. Record/Playback Sensitivity Check (DECK2)
Conditions
Measuring equipment: Same as item 16.
Test tape: TTA-602 (NORMAL)
Test point: TP8 (L-ch), TP9 (R-ch)
Input point: AUX (1 kHz)
1) Insert the test tape (TTA-602) into DECK2 and record the 1 kHz signal from AUX.
2) Adjust the attenuator so that TP8 and TP9 output level become 100 mV.
3) Play back the 1 kHz portion and check that the 1 kHz playback output level is within -2 dB +/- 3.5dB with respect to the record mode output
level.
ATTENUATOR
INPUT
OUTPUT
AUX(L)
AUX(R)
OUTPUT
AUDIO SIGNAL
GENERATOR
TP8
TP9
AC MILLIVOLTMETER
CH2
CH1
SET
(1KHz, 1V)
ELECTRICAL ADJUSTMENT-6/6
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299