IC DESCRIPTIONS
OEC0093B (IC1006)
No.
PORT
PIN NAME
I/O
DESCRIPTION
44
P17
32KHz_MONITOR
OUT Not used.
45
P67
T-REC_LED
OUT Output terminal control for T-REC-LED voltage drive.
46
P66
REC/OTR_LED
OUT Output terminal control for REC-LED voltage drive.
47
P65
ON_TIMER_LED
OUT Output terminal control for ON TIMER-LED voltage drive.
48
P64
PLAY_LED
OUT Output terminal control for PLAY-LED voltage drive.
49
P63
OTPB_LED
OUT Output terminal control for OTPB-LED voltage drive.
50
P62
TV POWER_ON-H
OUT For control of the user TV-power switch ON/OFF.
51
P61
VCR POWER_ON-H
OUT For control of the user VCR-power switch ON/OFF.
52
P60
CENT_LED
OUT Output terminal for center LED control.
53
P37
TAB_SW
IN
Input terminal for judge the tape if it has TAB or not.
54
P36
CTL_MONITOR
OUT Not used.
55
P35
MS_SENS_CTL
OUT Output terminal to drive sensor control.
56
VCC
VCC
—
AT +5V.
57
VSS
VSS
—
Ground.
58
P27
TRICK_PB-H
OUT Special effect playback.(CUE/REVIEW/STILL/SLOW etc)
59
SCL0
IIC_CLK_0
OUT Output Clock terminal for I2CBUS communication.
60
SDA0
IIC_DATA_0
OUT Output Data terminal for I2CBUS communication.
61
P24
TEXT RESET
OUT Output terminal of reset for TEXT_IC.
62
P23
SECAM-H
OUT Output signal of SECAM or NOT.
63
SCK1
AFC OFF-H
OUT Output terminal of CHROMA AFC cut or NOT.
64
SO1
SO1
OUT output terminal of FZTAT signal.
65
SI1
SI1
IN
input terminal of FZTAT signal.
66
P47
T'TEXT-H
OUT Output terminal of TEXT/MIX mode or TV mode.
67
P46
LDM_FWD
OUT Output signal to control the rotation direction of the loading motor.
68
P45
LDM_RVS
OUT
69
P44
REEL-S
IN
Input terminal of reel sensor SUPPLY.
70
P43
REEL-T
IN
Input terminal of reel sensor TAKE UP.
71
P42
CAP_FWD-L
OUT Capstan forward and backward command.
72
P41
CAP_FULL
OUT Output the HIGH during the acceleration force of Capstan Motor at SLOW mode.
73
P40
VV-H
OUT Output terminal for select Playback/Recording at the circuit of sound.
74
FWE
FWE
IN
Input terminal of FZTAT signal( L: low signal input).
75
X2
X2
OUT Subclock pulse (32.768KHz).
76
X1
X1
IN
Subclock pulse (32.768KHz).
77
/RES
/RES
IN
RESET will be done when the voltage goes to HIGH after the restart signal.
78
OSC1
OSC1
IN
Connect the main crystal (10MHz).
79
VSS
VSS
—
Ground.
80
OSC2
OSC2
OUT Connect the main crystal (10MHz).
81
VCL
VCL
IN
Condenser connection for VCC.
82
MD0
MD0
IN
Input terminal of FZTAT signal.
83
PWM2
CAP_LIMIT
OUT Switch the maximum out put current of the CAPSTAN Motor.
84
P33
EXT_IN-L
IN
Input terminal for Compulsion outside input.
85
P32
-
OUT Not used.
86
SV2
STAND_BY-H
OUT Output terminal control for STAND BY-LED.
F1-2