-28-
ELECTRICAL ADJUSTMENT-6/13 (K MODEL)
<FM ADJUSTMENT>
For adjusting FM, do wiring function and connection as in the following.
8. TRACKING CHECK
Requirement
• Measuring equipment : millivoltmeter
Test point : TP2, TP3, GND
(1) Adjust the S.S.G. setting to 83.0MHz of 75KHz variation, and 66dBuV for the output level.
(2) Check that the test point voltage is about 400mV.
SET
Standerd Signal Generaor
TP
Lch
Rch
GND
measuring equipment
Connect to the respective
Fig. 1
AC MILLIVOLTMETER
CH2
CH1
GND
TP2
TP3
GND
Summary of Contents for XR-M161HS(S)
Page 23: ... 22 FL ZCL 8 GRID ASSIGNMENT ANODE CONNECTION 1 1 GRID ASSIGNMENT ANODE CONNECTION ...
Page 39: ... 38 IC M62495AFP AUTO RESET IC BLOCK DIAGRAM 2 2 IC LC72131D ...
Page 51: ... 50 CD MECHANISM EXPLODED VIEW 1 2 DA 11T3C A M2 PIN 3 SW1 MOTOR C B 4 3 2 1 ...
Page 53: ... 52 CD MECHANISM EXPLODED VIEW 2 2 KSM 213CDM 1 2 COVER 3 4 5 SPINDLE MOTOR M3 MOTOR C B A M2 ...