FS2 v2.1r1
www.aja.com
51
• 4.1 SNMP Trap Destination 1
• 4.2 SNMP Trap Port 1
• 4.3 SNMP Trap Destination 2
• 4.4 SNMP Trap Port 2
In addition, the following parameters described below may affect SNMP messages:
• 5 Power Supply Alarm
• 6.1 Vid1 Format Alarm
• 6.2 Vid2 Format Alarm
• 7 Reference Alarm
Refer to
for a description of SNMP and how the FS2
supports it.
5 Power Supply
Alarm
This parameter controls how the FS2 alarm responds to power supply disconnection or
failure. If the FS2 will be connected using only one power cord and supply, you can
suppress the alarm. Changes to this setting are automatically saved.
6.1 Vid1 Format
Alarm
When set to
Normal
(default), an alarm is triggered whenever the selected input video
signal format of Video Proc 1 is incompatible with the selected output format (refer to the
matrix of inputs and compatibilities presented in
Chapter 2
). If you want the FS2 alarm to
only trigger on hardware failures, you can suppress the
Format Alarm
. The front panel Vid
1 FMT ERR LED lights when format errors are detected even if this parameter is set to
Suppress
. Changes to this setting are automatically saved.
6.2 Vid2 Format
Alarm
This parameter operates the same as 6.1 Vid1 Format Alarm above, but applies to the
input video signal format of Video Proc 2.
7 Reference Alarm
This parameter controls how the FS2 responds when one of the Video Processors has a
format that is incompatible with the Reference video signal. When set to
NORMAL,
the
alarm triggers if the Reference signal is not detected or is incompatible with the
processor format. If you want the FS2 Reference alarm to trigger only on hardware
failures, you can suppress the alarm. Changes to this setting are automatically saved.
NOTE:
For proper operation the Input reference signal must be stable and properly terminated using
a 75-ohm terminator on either the unused loop connector or the last piece of downstream
equipment to which the Ref Video is connected.
Normal (default)
Suppress
Alarm triggers if either internal power supply experiences a failure or is
disconnected from mains power.
Alarm will not be triggered by a power supply failure or disconnection
from power.
Normal (default)
Suppress
Alarm triggers if the format of the selected input video signal is
incompatible with the selected output format.
Alarm will not be triggered by a format incompatibility.
Normal (default)
Suppress
Alarm triggers if the reference signal is not detected or is
incompatible with the processor format.
Alarm will not be triggered by reference errors.
USO