FS3 Frame Synchronizer/Converter v1.1r1 38 www.aja.com
1 Remote Control
This parameter determines whether the FS3 panel responds to controls locally
from the front panel, from a network attached computer with a web browser, or
both. The selected mode is indicated by the color of the REMOTE LED.
Local + Remote (default)
Local Only
Remote Only
Control from the front panel, a remote control panel, or a network-
attached browser. The
REMOTE
LED lights amber.
Control only from the front panel (browsers cannot change
parameters). The
REMOTE
LED lights green.
Control only from a network attached browser or remote control
panel. The
REMOTE
LED lights red.
1.1 Authentication
This parameter enables or disables an authentication login requirement. By
default this parameter is set to Disabled.
When you select Login via the front panel parameter, you must then go to the
browser interface to perform a login each time you access the FS3. The browser
presents the login screen first, requiring you to log in before you can access any
other browser screens. The password is initially set to the default value, but you
can change it using the Remote browser screen.
The default password is password.
NOTE: If authentication is used, it provides only a minimum security safeguard against
unauthorized use of the FS3. The authentication mechanism is simple and does
not provide robust security.
Disabled
(default)
Login
Disables the requirement for a login password. No password is
needed.
Login is required via the web browser interface before changes
can be made. After selecting Login, depending on the browser a
new browser window may be necessary (i.e. just a page refresh or
reload may not get rid of the login page).
2.1–4 GPI IN 1–4 Response
The setting of this parameter determines what happens when a GPI trigger is
received at the FS3’s GPI Inputs (1–4). A GPI Trigger is defined as a TTL low voltage
level (0 to 0.8V with respect to its isolated ground pin). The GPI interface pinout
and specifications are discussed in
. Input video sources
selected by GPI trigger remain selected until the trigger is released. GPI Inputs
light the front panel EXT LED when triggered.